Pepperl+Fuchs FB6215BR
Digital Output
- 4-channel
- Outputs Ex ia
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- Line fault detection (LFD)
- Positive or negative logic selectable
- Simulation mode for service operations (forcing)
- Permanently self-monitoring
- Output with watchdog
Item Number:
FB6215BR
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Power consumption | 0.15 W |
Power dissipation | 3 W |
Relative humidity | 95 % non-condensing |
Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance |
LED indication | LED green: supply LED red: line fault , red flashing: communication error |
Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication |
Dimensions | 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) |
EAC approval | Russia: RU C-IT.MIII06.B.00129 |
System information | The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. |
Electromagnetic compatibility | NE 21 |
EU-Type Examination Certificate | PTB 97 ATEX 1074 U |
Internal resistor | max. 90 Ω |
Interface | manufacturer-specific bus to standard com unit |
Shock resistance | EN 60068-2-27 |
Open loop voltage | 16.6 V |
Degree of protection | IEC 60529 |
Connection | backplane bus |
Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
ATEX approval | PTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U |
Coding | optional mechanical coding via front socket |
Connection | channel I: 9+, 10-; channel II: 11+, 12-; channel III: 13+, 14-; channel IV: 15+, 16- |
Damaging gas | EN 60068-2-42 |
Mass | approx. 750 g |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Environmental test | EN 60068-2-14 |
Input voltage range | 18.5 ... 32 V DC (SELV/PELV) booster voltage |
Number of channels | 4 |
Reaction time | 10 s |
Occupied slots | 2 |
Relative humidity | EN 60068-2-56 |
Response time | 10 ms (depending on bus cycle time) |
Vibration resistance | EN 60068-2-6 |
Rated voltage | 12 V DC , only in connection with the power supplies FB92** |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Line fault detection | can be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms) |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) |
Current limit | 70 mA |
Connection | backplane bus / 24 V booster via wire ends |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
People also buy
Comments
No comments yet