Pepperl+Fuchs FB7204B3 Universal Input/Output (HART)

Pepperl+Fuchs FB7204B3
Item Number: FB7204B3
  • 4-channel
  • Inputs Ex ia, Outputs Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Analog input, digital input,
    analog output, digital output
  • Supply circuit 21.5 V (4 mA)
  • HART communication via field bus or service bus
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD): one LED per channel
  • Permanently self-monitoring
The price is not final. Please check with the manager!
1361.36
Quantity
-
+
Total price: 1361.36
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Connectionterminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-
Power consumption3 W
InputEx ia
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Open loop voltagemin. 22.7 V
Dimensions28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch)
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
ATEX approvalPresafe 19 ATEX 14057U
OutputEx ia
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Transmitter supply voltagemin. 15 V at 20 mA ; 21.5 V at 4 mA
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Damaging gasEN 60068-2-42
LED indicationPower LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (1-4) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1)
Configuration LED (AI, AO, DI, DO) white: selected channel mode
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Rated voltageUse only in connection with the power supplies FB92**
Line fault detectioncan be switched on/off for each channel via configuration tool
Codingoptional mechanical coding via front socket
Massapprox. 425 g
Connectionterminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-
Resolution12 Bit (0 ... 26 mA)
Connectionbackplane bus
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Interfacemanufacturer-specific bus to standard com unit
Number of channels4
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Occupied slots1
Connectionbackplane bus
Number of channels4
Environmental testEN 60068-2-14
HART communicationyes
Internal resistor385 Ω
Connectionterminals 1+, 2-, 3+, 4-, 5+, 6-, 7+, 8-
Current0 ... 20 mA short-circuit protected
Current limit22 mA
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
HART secondary variableyes
Power dissipation2 W
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Degree of protectionIEC 60529
HART communicationyes
Drive capability12 V / 22 mA
Refresh timeapprox. 100 ms (4 channels)
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
EU-type examination certificatePresafe 19 ATEX 14057U
HART secondary variableyes
IECEx approvalIECEx PRE 19.0012U
Electromagnetic compatibilityNE 21
Watchdogoutput off 0.5 s after serious fault
Loadmax. 750 Ω at 20 mA
Number of channels4
Relative humidity95 % non-condensing
Vibration resistanceEN 60068-2-6
Input resistance15 Ω
Number of channels4
Connectionterminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-
Line fault detectioncan be switched on/off for each channel via configuration tool
Relative humidityEN 60068-2-56
Shock resistanceEN 60068-2-27

Comments

No comments yet

Write a comment