Pepperl+Fuchs FB7204B3 Universal Input/Output (HART)


Item Number: FB7204B3
- 4-channel
- Inputs Ex ia, Outputs Ex ia
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- Analog input, digital input,
analog output, digital output - Supply circuit 21.5 V (4 mA)
- HART communication via field bus or service bus
- Simulation mode for service operations (forcing)
- Line fault detection (LFD): one LED per channel
- Permanently self-monitoring
- Overview
- Datasheet
- Alternative numbers
- Comments
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Connection | terminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8- |
Power consumption | 3 W |
Input | Ex ia |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Open loop voltage | min. 22.7 V |
Dimensions | 28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch) |
Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool |
ATEX approval | Presafe 19 ATEX 14057U |
Output | Ex ia |
System information | The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. |
Transmitter supply voltage | min. 15 V at 20 mA ; 21.5 V at 4 mA |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) |
Damaging gas | EN 60068-2-42 |
LED indication | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Configuration LED (AI, AO, DI, DO) white: selected channel mode |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Rated voltage | Use only in connection with the power supplies FB92** |
Line fault detection | can be switched on/off for each channel via configuration tool |
Coding | optional mechanical coding via front socket |
Mass | approx. 425 g |
Connection | terminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8- |
Resolution | 12 Bit (0 ... 26 mA) |
Connection | backplane bus |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Interface | manufacturer-specific bus to standard com unit |
Number of channels | 4 |
Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
Occupied slots | 1 |
Connection | backplane bus |
Number of channels | 4 |
Environmental test | EN 60068-2-14 |
HART communication | yes |
Internal resistor | 385 Ω |
Connection | terminals 1+, 2-, 3+, 4-, 5+, 6-, 7+, 8- |
Current | 0 ... 20 mA short-circuit protected |
Current limit | 22 mA |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
HART secondary variable | yes |
Power dissipation | 2 W |
Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance |
Degree of protection | IEC 60529 |
HART communication | yes |
Drive capability | 12 V / 22 mA |
Refresh time | approx. 100 ms (4 channels) |
Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool |
EU-type examination certificate | Presafe 19 ATEX 14057U |
HART secondary variable | yes |
IECEx approval | IECEx PRE 19.0012U |
Electromagnetic compatibility | NE 21 |
Watchdog | output off 0.5 s after serious fault |
Load | max. 750 Ω at 20 mA |
Number of channels | 4 |
Relative humidity | 95 % non-condensing |
Vibration resistance | EN 60068-2-6 |
Input resistance | 15 Ω |
Number of channels | 4 |
Connection | terminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8- |
Line fault detection | can be switched on/off for each channel via configuration tool |
Relative humidity | EN 60068-2-56 |
Shock resistance | EN 60068-2-27 |