Pepperl+Fuchs FF MIO
FOUNDATION Fieldbus Modular I/O
We ship to United States of America!
- For 20 analog or 40 digital channels
- Sensors in Zone 0/Div. 1 (depending on module assembly)
- Installation in Zone 2, Div. 2 or safe area
- HART communication via service bus
- For FOUNDATION Fieldbus H1
- Configured via the process control system
- Non-volatile memory for configuration and parameter settings
- Quick communication set-up
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Module can be exchanged under voltage
Item Number:
FF MIO
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Power consumption | max. 39 W , available output power for Zone 2 applications 5 W (5V), 20 W (12V), else 5 W (5V), 35 W (12V) |
Connection | backplane LB9035A |
Bus length | max. 1900 m (must not be exceeded by the sum of all trunk and spur lines) |
Degree of protection | IP20 |
Spur length | max. 120 m (depending on the number of field devices. Modular I/O station = 1 field device) |
Statement of conformity | PF 08 CERT 1234 X |
Auxiliary energy | 24 V DC Trunk load 10 mA according to FF standard. |
Number of channels per station | max. 20 analog, max. 40 digital |
Dimensions | 275 x 127 mm (10.8 x 5 inch) |
Degree of protection | IEC 60529 |
Number of stations per bus line | 1 or 2, depending on the required response times |
Rated voltage | 24 V DC |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Addressing | via PCS (software) |
LED indicator | Com unit LB8110*: LED green (power supply): on = operating, fast flash = cold start LED red (collective alarm): on = internal fault, flashing = no fieldbus LED yellow (operating mode): flashing = active Power supply LB9006C: LED green (power supply): off in case of loss of 24 V or 12 V or 5 V I/O modules (refer to the table with compatible modules for order codes): Power LED green: supply Diagnostic LED red: module fault, red flashing: communication error Status LED red: line fault Status LED yellow: signal (Live Zero status) |
Station connection | directly at the trunk or via spur protector |
Buy Pepperl+Fuchs FF MIO with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is an online electronic supply store. We offer only original products with all manufacturer's warranty. All your orders and products can be shipped in one delivery. Good price and good delivery times are our main goals. We always make open communication with our customers. Make an order and we will give you the best possible proposal.