Pepperl+Fuchs FF MIO
FOUNDATION Fieldbus Modular I/O

Pepperl+Fuchs FF MIO
We ship to United States of America!
  • For 20 analog or 40 digital channels
  • Sensors in Zone 0/Div. 1 (depending on module assembly)
  • Installation in Zone 2, Div. 2 or safe area
  • HART communication via service bus
  • For FOUNDATION Fieldbus H1
  • Configured via the process control system
  • Non-volatile memory for configuration and parameter settings
  • Quick communication set-up
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Module can be exchanged under voltage
Item Number: FF MIO
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +
Power consumptionmax. 39 W , available output power for Zone 2 applications 5 W (5V), 20 W (12V), else 5 W (5V), 35 W (12V)
Connectionbackplane LB9035A
Bus lengthmax. 1900 m
(must not be exceeded by the sum of all trunk and spur lines)
Degree of protectionIP20
Spur lengthmax. 120 m
(depending on the number of field devices. Modular I/O station = 1 field device)
Statement of conformityPF 08 CERT 1234 X
Auxiliary energy24 V DC
Trunk load 10 mA according to FF standard.
Number of channels per stationmax. 20 analog, max. 40 digital
Dimensions275 x 127 mm (10.8 x 5 inch)
Degree of protectionIEC 60529
Number of stations per bus line1 or 2, depending on the required response times
Rated voltage24 V DC
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Addressingvia PCS (software)
LED indicatorCom unit LB8110*:
LED green (power supply): on = operating, fast flash = cold start
LED red (collective alarm): on = internal fault, flashing = no fieldbus
LED yellow (operating mode): flashing = active
Power supply LB9006C:
LED green (power supply): off in case of loss of 24 V or 12 V or 5 V
I/O modules (refer to the table with compatible modules for order codes):
Power LED green: supply
Diagnostic LED red: module fault, red flashing: communication error
Status LED red: line fault
Status LED yellow: signal (Live Zero status)
Station connectiondirectly at the trunk or via spur protector

Buy Pepperl+Fuchs FF MIO with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is an online electronic supply store. We offer only original products with all manufacturer's warranty. All your orders and products can be shipped in one delivery. Good price and good delivery times are our main goals. We always make open communication with our customers. Make an order and we will give you the best possible proposal.