Pepperl+Fuchs HD2-GTR-4PA.PN
PROFINET Power Hub, Gateway Module

Pepperl+Fuchs HD2-GTR-4PA.PN
  • Gateway PROFINET RT to 4 x PROFIBUS PA segments
  • Up to 32 devices per PROFIBUS PA segment
  • Installation in Zone 2/Class I, Div. 2
  • Ring and system redundancy
  • Integrated webserver for diagnostics
Item Number: HD2-GTR-4PA.PN
3750.91
-
+
Total price: 3750.91
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

CH/PROFIBUS DPfunctional insulation acc. to IEC 61010, rated insulation voltage 50 Veff

Design / MountingMotherboard based
CH/CHfunctional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
Statement of conformityTГњV 15 ATEX 7735 X
Rated currenttyp. 135 mA
Degree of protectionIEC 60529
PROFIBUS DP/Supplyfunctional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
Ambient temperature-40 ... 60 В°C (-40 ... 140 В°F) vertically mounted , -40 ... 70 В°C (-40 ... 158 В°F) horizontally mounted
Transfer rate100 MBit/s
Rated voltage19.2 ... 35 V SELV/PELV
LED DP/ERRred 2 Hz flashing: DP error ; red: Hardware error
LED ETH2 LINKgreen: link status
Fieldbus standardIEC 61158-2
Fieldbus typePROFIBUS PA
LED Red.yellow: redundant operation primary device ; yellow 2 Hz flashing: synchronization or redundancy not available
Housing materialPolycarbonate
LED ETH2 ACTyellow: activity status
Ethernet InterfaceConnector , 2x RJ45
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
LED ERRred 2 Hz flashing: Ethernet error
Vibration resistance1 g , 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Mountingmotherboard mounting
Electromagnetic compatibilityNE 21:2011
Housing height106 mm
Shock resistance15 g 11 ms
LED PWRgreen: Power on
Mass250 g
Shock resistanceEN 60068-2-27
All circuits/FEfunctional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
IECEx approvalIECEx TUR 16.0007X
Number of segments4
Degree of protectionIP20
Number of devices per segmentmax. 32
Housing width40 mm
LED ETH1 LINK 2green: link status
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
ProtocolPROFINET
Ethernet/Supplyfunctional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
Marine approvalpending
LED ETH1 ACTyellow: activity status
Vibration resistanceEN 60068-2-6
Number of ports2
Power dissipationapprox. 3.5 W
LED Seg 1...4red 2 Hz flashing: PA error, red and LED DP/ERR red: MAU error
RedundancyRing (MRP) , System S2
CH/Ethernetfunctional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
Relative humidity< 95 % non-condensing
Housing depth128 mm

Comments

No comments yet

Write a comment