Pepperl+Fuchs HiC2027ES
SMART Transmitter Power Supply
We ship to United States of America!
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Input for 2-wire SMART transmitters and current sources
- Signal splitter (1 input and 2 outputs)
- Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V
- Up to SIL 3 acc. to IEC 61508
Item Number:
HiC2027ES
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
ConnectionSL1: 8a(+), 7a(-), channel 1: source and sink
SL1: 10a(+), 9a(-), channel 2: source and sink
Output/Output | functional insulation, rated insulation voltage 50 V AC |
Rise time/fall time | 2 ms |
IECEx approval | IECEx BAS 13.0042X |
Deviation | Iout < 20 µA (0.1 %); Vout < 10 mV (0.2 %) incl. calibration, linearity, hysteresis and fluctuation of supply voltage, at 20 ?°C (68 ?°F), 0/4 ... 20 mA, 0/1 ... 5 V |
Connection | SL1: 1a, 1b(-); 2a, 2b(+) |
Equipment | terminals 5a, 5b |
Dimensions | 12.5 x 128 x 106 mm (0.5 x 5.1 x 4.2 inch) |
Coding | pin 2 and 3 trimmed For further information see system description. |
Available voltage | SL2: 5a(+), 5b(-): ≥ 16 V at 20 mA , ≥ 18.5 V at 4 mA |
EU-type examination certificate | BASEEFA 13 ATEX 0075 X |
Note | Both output loads must be connected to ensure complete and correct operation within the technical specification. |
Power dissipation | approx. 1.4 W at 20 mA transfer current, 250 Ω in both outputs |
Rated voltage | 18 ... 30 V DC bus powered via Termination Board |
Protection against electrical shock | UL 61010-1:2012 |
Ripple | max. 50 µA rms |
Load | channel 1: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V) channel 2: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V) |
Connection side | control side |
Settling time | 6 ms |
Output signal | 0/4 ... 20 mA or 0/1 ... 5 V |
Voltage drop | SL2: 1a(+), 1b(-), 7a(-): ≤ 6.1 V at 20 mA |
Mass | approx. 100 g |
Ripple | within the supply tolerance |
Labeling | space for labeling at the front |
Equipment | terminals 1a, 1b, 7a |
Connection side | field side |
Output/power supply | functional insulation, rated insulation voltage 50 V AC |
Certificate | BASEEFA 13 ATEX 0076 X |
Electromagnetic compatibility | NE 21:2012 EN 61326-3-2:2008 |
Input signal | 0/4 ... 20 mA |
Signal type | Analog input |
Power consumption | 2 W |
Connection | SL2: 5a(+), 5b(-): sink SL2: 1a(+), 1b(-), 7a(-): source |
Display elements | LED |
Control elements | DIP-switch |
Configuration | via DIP switches |
Mounting | on Termination Board |
Frequency range | field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 6 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0.3 ... 6 kHz (-3 dB) |
Degree of protection | IP20 |
Degree of protection | IEC 60529:2001 |
Input resistance | SL2: 5a(+), 5b(-): max. 500 Ω (BRAIN) (250 Ω load) |
Safety Integrity Level (SIL) | SIL 2 |
Short-circuit current | SL2: 5a(+), 5b(-): 25 mA |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Ambient temperature | -20 ... 60 ?°C (-4 ... 140 ?°F) |
Buy Pepperl+Fuchs HiC2027ES with the best possible price and delivery terms on eltra-trade.com
Find the industrial control components you need at eltra-trade.com. Our catalog includes a variety of sizes and types, all available for fast delivery. Enjoy competitive pricing and excellent customer service. Trust us to fulfill your automation equipment requirements.
People also buy