Pepperl+Fuchs HiD2029
SMART Transmitter Power Supply

Pepperl+Fuchs HiD2029

This item is out of production!

  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • 2-wire SMART transmitters or current sources
  • Output for 4 mA ... 20 mA or 1 V ... 5 V
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508
Item Number: HiD2029
528.00
-
+
Total price: 528.00
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

This item is out of production!

Check with the manager for a replacement.

ConnectionSL1: 8a(+), 7a(-)
Calibrated accuracy< В± 0.1 % of full-scale value (current output)
CertificatePF 11 CERT 2109 X
ConnectionSL1: 1a(-), 1b(-); 2a(+), 2b(+)
IECEx approvalIECEx TUN 04.0012
Influence of load< В± 0.1 % of full-scale value from 0 ... 650 andOmega;
Power dissipation1.05 W at 24 V
Electromagnetic compatibilityNE 21:2006
For further information see system description.
Input resistance40 andOmega; , for current source
Frequency rangecommunication channel: 0.5 ... 40 kHz within 3 db, (-6 db at 100 kHz), Tx to output and output to Tx,
suitable for use with SMART transmitters using HART or similar protocol
Rated current60 mA at 24 V, 20 mA output
Connection sidefield side
Response time70 ms , 10 ... 90 % step change
Voltagemin. 15.5 V at 20 mA
Output signal4 ... 20 mA or 1 ... 5 V (on 250 andOmega;, 0.1 % internal shunt)
Influence of temperature< В± 0.01 %/ K
ConnectionSL1: 6b
Load0 ... 650 andOmega;
Output typeopen collector transistor
fault bus signal
Degree of protectionIP20
Signal levelno fault: 1 mA ... 23.5 mA input current
fault detection: < 0.2 mA or > 24 mA input current
Configurationvia DIP switches
EU-Type Examination CertificateCESI 02 ATEX 086
Linearity< В± 0.05 % of full-scale value
Labelingspace for labeling at the front
Rated voltage20.4 ... 30 V DC bus powered via Termination Board
Degree of protectionIEC 60529
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Dimensions18 x 106 x 128 mm (0.7 x 4.2 x 5 inch)
Display elementsLEDs
Communicationpass-through of HART signal to safe area
The current sink terminals 4 and 7 do not pass the HART signal to safe area.
Safety Integrity Level (SIL)SIL 2
ConnectionSL2: 5a(+), 5b, 7a(-)
Input current4 ... 20 mA , current limit 26 mA
Mountingon Termination Board
Control elementsDIP-switch
Ripple10 mV eff
Massapprox. 140 g
Ripple10 mV eff on a load of 250 andOmega;
Connection sidecontrol side
Signal typeAnalog input

Comments

No comments yet