Pepperl+Fuchs HiD2030SK SMART Transmitter Power Supply


Item Number: HiD2030SK
- 2-channel isolated barrier
- 24 V DC supply (bus powered)
- 2-wire SMART transmitters or current sources
- Usable as signal splitter (1 input and 2 outputs)
- Dual output 4 mA ... 20 mA, current sink
- Line fault detection (LFD)
- Up to SIL 2 acc. to IEC 61508
- Overview
- Datasheet
- Alternative numbers
- Comments
Coding | pin 1 and 3 trimmed For further information see system description. |
Dimensions | 18 x 106 x 128 mm (0.7 x 4.2 x 5 inch) |
Connection | SL1: 8a(+), 7a(-); 10a(+), 9a(-) |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Output type | open collector transistor (common to both channels) fault bus signal, collective error message |
Relative humidity | 5 ... 90 %, non-condensing up to 35 В°C (95 В°F) |
Rated voltage | 20.4 ... 30 V DC bus powered via Termination Board |
Connection side | field side |
Calibrated accuracy | < В± 0.1 % of full-scale value |
Communication | pass-through of HART signal to safe area The current sink terminals 4, 7 and 5, 6 do not pass the HART signal to safe area. |
Frequency range | communication channel: 0.5 ... 40 kHz within 3 db, (-6 db at 100 kHz), Tx to output and output to Tx, suitable for use with SMART transmitters using HART or similar protocol |
Display elements | LEDs |
Degree of protection | IP20 |
Mass | approx. 140 g |
Signal level | no fault: 1 mA ... 23.5 mA input current fault detection: < 0.2 mA or > 24 mA input current |
Output/Output | functional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff |
Electromagnetic compatibility | NE 21:2006 For further information see system description. |
Input current | 4 ... 20 mA , current limit 26 mA |
EU-type examination certificate | CESI 02 ATEX 086 |
Output | sink mode from external supply |
Rated current | 40 mA at 24 V, 20 mA output (per channel) |
Signal type | Analog input |
Safety Integrity Level (SIL) | SIL 2 |
Connection | SL1: 6b |
Influence of temperature | < В± 0.01 %/ K |
Labeling | space for labeling at the front |
Ripple | 10 mV eff |
Degree of protection | IEC 60529 |
Output/power supply | functional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff |
IECEx approval | IECEx TUN 04.0012 |
Connection | SL2: 5a(+), 5b, 7a(-); 1a(+), 1b, 3b(-) |
Connection side | control side |
Linearity | < В± 0.05 % of full-scale value |
Output signal | 4 ... 20 mA , current limit 24 mA |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Mounting | on Termination Board |
Voltage | working voltage 7 ... 30 V |
Power dissipation | 1.05 W at 20 mA and 24 V external from PCS or PLC (per channel) |
Connection | SL1: 1a(-), 1b(-); 2a(+), 2b(+) |
Input resistance | 40 Ω , for current source |
Certificate | PF 11 CERT 2109 X |
Voltage | min. 15.5 V at 20 mA |
Response time | 70 ms , 10 ... 90 % step change |