Pepperl+Fuchs HiD2062

Temperature Converter
Pepperl+Fuchs HiD2062
Price on Request
One click request
Configurationvia DIP switches
via potentiometer
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Degree of protectionIP20
Compensation errorВ± 0.5 K В± 0.05 K deviation from reference of 20 В°C (68 В°F)
ConnectionSL2:
5a(+), 7a(-); 1a(+), 1b(-): thermocouples type E, J, K, N, R, S, T
5a(+), 7b(-); 1a(+), 3b(-): thermocouple type B and mV input
5b(+), 7b(-); 3a(+), 3b(-): cold junction compensation (CJC)
Display elementsLED
Labelingspace for labeling at the front
Mountingon Termination Board
Line fault detectionsensor burnout 25 nA, upscale or downscale (selectable)
Rise time/fall timetyp. 150 ms
Output signal4 ... 20 mA or 1 ... 5 V (on 250 andOmega;, 0.1 % internal shunt)
IECEx approvalIECEx TUN 04.0012
EU-Type Examination CertificateCESI 02 ATEX 086
Accuracy< В± 0.1 % of full-scale value (current output)
Massapprox. 140 g
Connection sidecontrol side
Connection sidefield side
ConnectionSL1: 1a(-), 1b(-); 2a(+), 2b(+)
Control elementsDIP-switch
potentiometer
Ripple10 mVrms (at load 250 andOmega;)
Influence of temperature< В± 0.01 %/K on zero and span
Influence of load< В± 0.1 % of full-scale value from 0 ... 650 andOmega;
Electromagnetic compatibilityNE 21:2006
For further information see system description.
Rated voltage20.4 ... 30 V DC bus powered via Termination Board
CertificatePF 11 CERT 2109 X
Signal typeAnalog input
Load0 ... 650 andOmega;
Degree of protectionIEC 60529
ConnectionSL1: 8a(+), 7a(-); 10a(+), 9a(-)
Zero suppressionВ± 500 % of span
Measurement range-10 ... 100 mV
Power dissipation0.6 W at 24 V (per channel)
Dimensions18 x 106 x 128 mm (0.7 x 4.2 x 5 inch)
Thermocouplestype B, E, J, K, N, R, S, T (IEC 584-1), type L (GOST)
Linearity< В± 0.1 % of full-scale value (terminal based mV input to mA output of thermocouples)
Rated current30 mA at 24 V, 20 mA output (per channel)
Span2.6 ... 100 mV
in international format without spaces