- Max. 4 read/write heads connectable
- Alternative 2 read/write heads and 2 trigger sensors can be connected
- LC display with background lightning
- Direct operation via 4 keys
- LED status indicator of bus communication and read/write heads
Item Number:
IC-KP-B6-SUBD
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
LEDs 1, 2, 3, 4 | Status indicator for read/write heads green: command at read/write head active yellow: approx. 1 second long, if command was successfully executed |
Rated operating voltage | 20 ... 30 V DC , PELV |
Installation | snap-on to 35 mm standard rail or screw fixing |
Degree of protection | IEC 60529:2001 |
Current consumption | 2 A incl. read/write heads |
Storage temperature | -30 ... 80 В°C (-22 ... 176 В°F) |
Ripple | 10 % at 30 V DC |
Connection | Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M6 earthing screw PROFIBUS: 9-pin Sub-D connector |
Galvanic isolation | basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff |
Physical | RS-485 |
LED Bus Error | red: Bus error |
Transfer rate | 9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing |
Protocol | PROFIBUS DP acc. to EN 50170 |
UL File Number | E87056 |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Degree of protection | IP40 |
Number of read/write heads | max. 4 alternative 2 read/write heads and 2 trigger sensors |
LED Data Exch | green: Slave is at state ""Data Exchange"" |
Button | 4 keys: ESC, up, down and return |
Climatic conditions | air humidity max. 96 % |
LED PWR/ERR | green: power on red: Hardware fault |
Shock and impact resistance | Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6 Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27 |
Mass | approx. 1000 g |
LC display | two-line multi-function display with 12 characters per line configuration of the control interface and display of connected read/write heads as additional pictograms; easy and direct selection of operating commands and addressing |
LED DPV1 | Yellow: not used |
LED UL | green: Interface Power ON/OK |
Power consumption | 3.5 W Without read/write heads |
People also buy