Rated operating voltage20 ... 30 V DC , PELV
LED RxDgreen: flashes in rhythm of receiving data
Ripple 10 % at 30 V DC
LED CH1green: read head detected
red: Configuration error
MTTFd160 a
LED 1Status indicator for read/write head
green: command at read/write head active
yellow: approx. 1 second long, if command was successfully executed
Degree of protectionIP67
Interface typeserial
UL File NumberE87056
Diagnostic Coverage (DC)0 %
Connectionread/write head: M12 plug connection, 4-pin, screened,
Power supply: M12 connector
Protective earth: M4 earthing screw
RS 232: M12 plug connection
RS 485: M12 connector
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Physical RS-485
Physical RS 232
Climatic conditionsair humidity max. 96 %
Salt spray resistant to EN 60068-2-52
Massapprox. 300 g
ProtocolASCII
Galvanic isolationbasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
LED TxDgreen: flashes in rhythm with the transmitted data
Shock and impact resistanceOscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6
Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27
LED PWR/ERRgreen: power on
red: Hardware fault
Interface typeserial
Degree of protectionIEC 60529:2001
Transfer rate1200; 2400; 4800; 9600; 19200; 38400 Bit/s
Number of read/write headsmax. 1
Mission Time (TM)10 a
Installationscrew fixing
ProtocolASCII
Transfer rate1200; 2400; 4800; 9600; 19200; 38400 Bit/s
Power consumption2 W Without read/write head
Current consumption 4 A incl. read/write heads
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)