Pepperl+Fuchs IUH-F190-V1-FR2-02
Read/write head

- Flexible UHF read/write head with medium detection range
- Ready-made PLC function blocks designed for quick and easy system integration
- Compact and robust housing for harsh industrial environments
- Switchable antenna polarization guarantees reliable tag detection and enhances process flow
- Multi-tag reading of up to 40 tags ensures increased productivity
- For connection to IDENTControl control interface

Item Number:
IUH-F190-V1-FR2-02
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Datasheet
- Alternative numbers
- Comments
Emitted power | 3 andhellip; 1250 mW EIRP adjustable |
Degree of protection | IP67 |
Operating distance | typ. 2 m |
LED blue | Transmission mode |
Mass | 860 g |
Electromagnetic compatibility | EN 301489-1 V2.1.1:2017 EN 301489-3 V2.1.1:2017 |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
FCC approval | This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. |
Current consumption | 450 mA |
Classification | Environmental condition A (controlled environment) |
UL File Number | E468231 |
Supply | from the IDENTControl |
Surge protection | category 2 |
Degree of protection | EN 60529:2000 |
LED yellow | Read/write operation successful |
LED green | Power on |
IC approval | This device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prГ©sent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisГ©e aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioГ©lectrique subi, mГЄme si le brouillage est susceptible d'en compromettre le fonctionnement. |
Connection | M12 x 1 connector |
Safety | EN 62368-1:2014+AC:2015 |
Pollution degree | 2 |
Operating frequency | 902 MHz andhellip; 928 MHz: USA, Canada, Mexico, Argentina Transmission licenses for other countries on request |
Power consumption | 9 W |
Ambient temperature | -20 ... 70 В°C (-4 ... 158 В°F) (Operation with nontransmission periods, adjustable) -20 ... 60 В°C (-4 ... 140 В°F) (Continuous transmission mode) |
Radio approval | USA: FCC IREIUHF190V1B Canada: 7037A-IUHF190V1B |
People also buy
Comments
No comments yet