Pepperl+Fuchs KCD2-RR-Ex1.SP
Temperature Repeater
We ship to United States of America!
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Resistance and RTD input (Pt100, Pt500, Pt1000)
- Resistance output
- Accuracy 0.1 %
- Line fault detection (LFD) for Pt100
- Housing width 12.5 mm
- Up to SIL 2 acc. to IEC 61508
Item Number:
KCD2-RR-Ex1.SP
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Current0 ... 10 mA
Connection side | control side |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Connection | terminals 1, 2, 3, 4 |
Display elements | LED |
Degree of protection | IEC 60529:2001 |
Labeling | space for labeling at the front |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Degree of protection | IP20 |
Available voltage | 0 ... 4.2 V |
Ripple | within the supply tolerance |
Input/power supply | reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff |
Control elements | DIP-switch |
Connection side | field side |
IECEx approval | IECEx BAS 10.0024 IECEx BAS 10.0025X |
Protection against electrical shock | UL 61010-1 |
Available voltage | 9 V |
Output/power supply | functional insulation, rated insulation voltage 50 V AC |
Connection | Power Rail or terminals 9+, 10- |
Configuration | via DIP switches |
Lead resistance | 10 % of resistance value |
Input/Output | reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff |
Mass | approx. 100 g |
Deviation | Im 1 mA: В±0.1 % of Rm or В± 0.1 andOmega; (the larger value is applicable) Im < 1 mA: accuracy reduces in proportion to Im. e. g. Im = 0.1 mA: В± 1 % of Rm or 1 andOmega; (the larger value is applicable). |
Signal type | Analog input |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Safety Integrity Level (SIL) | SIL 2 |
Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 |
Electromagnetic compatibility | NE 21:2011 |
Certificate | BASEEFA 10 ATEX 0062X |
Line fault detection | 8 nA |
Accuracy | 0.1 % |
Rated current | < 20 mA |
Power consumption | 0.35 W (24 V and 1 mA sense current) |
Optional accessories | - power feed module KFD2-EB2(.R4A.B)(.SP) - universal power rail UPR-03(-M)(-S) - profile rail K-DUCT-BU(-UPR-03) |
Fault signal | < 10 andOmega; or > 400 andOmega;, depending on lead disconnected (measuring current 1 mA) > 400 andOmega;, terminal 3 lead disconnected in 2-/4-wire (measuring current 0.3 mA) |
Line fault detection | yes , at Pt100 |
Rise time | signal response time 2 ms (10 ... 90 %) response to application of Im: Rm > 50 andOmega; and Im < 5mA: < 5ms response to application of Im: Rm > 30 andOmega; and Im < 5mA: < 10ms response to application of Im: Rm > 18 andOmega; and Im < 5mA: < 20ms |
Connection | spring terminals |
Connection | terminals 5-, 7-, 6+, 8+ |
Transmission range | 0 ... 10 mA |
Rated voltage | 19 ... 30 V DC |
EU-Type Examination Certificate | BASEEFA 10 ATEX 0061 |
Buy Pepperl+Fuchs KCD2-RR-Ex1.SP with the best possible price and delivery terms on eltra-trade.com
Find the industrial control components you need at eltra-trade.com. Our catalog offers a variety of sizes and types, all available for prompt delivery. Enjoy competitive pricing and excellent customer service. Trust us to fulfill your automation equipment requirements efficiently and reliably.
People also buy
Comments