- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Resistance and RTD input (Pt100, Pt500, Pt1000)
- Resistance output
- Accuracy 0.1 %
- Line fault detection (LFD) for Pt100
- Housing width 12.5 mm
- Connection via spring terminals with push-in connection technology
- Up to SIL 2 acc. to IEC 61508
Item Number:
KCD2-RR2-Ex1.SP
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Ambient temperature | -40 ... 70 ?°C (-40 ... 158 ?°F) |
EU-type examination certificate | BASEEFA 10 ATEX 0061X |
Rise time/fall time | ≤ 2 ms (10 ... 90%) |
UL approval | E106378 |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Connection | terminals 1, 2, 3, 4 |
Lead resistance | ≤ 10 % of resistance value |
Connection | Power Rail or terminals 9+, 10- |
Safety Integrity Level (SIL) | SIL 2 |
Connection side | control side |
Line fault detection | < 30 nA |
Electromagnetic compatibility | NE 21:2017 EN IEC 61326-3-2:2018 |
Optional accessories | - power feed module KFD2-EB2(.R4A.B)(.SP) - universal power rail UPR-03(-M)(-S) - profile rail K-DUCT-BU(-UPR-03) - insertion bridge EBP 2- 5 |
Reverse polarity protection | for I < 10 mA or U < 20 V |
Available voltage | 0 ... 4.2 V |
Connection side | field side |
Power consumption | 0.35 W (24 V and 1 mA sense current), 0.85 W (30 V and 10 mA sense current) |
Available voltage | 7 V |
Transmission range | 0 ... 10 mA |
Configuration | via DIP switches |
Certificate | BASEEFA 10 ATEX 0062X |
Deviation | Im ≥ 1 mA: ?±0.1 % of Rm or ?± 0.1 Ω (the larger value is applicable) Im < 1 mA: accuracy reduces in proportion to Im. e. g. Im = 0.1 mA: ?± 1 % of Rm or 1 Ω (the larger value is applicable). |
Degree of protection | IP20 |
Connection | spring terminals |
Display elements | LED |
Signal type | Analog input |
Fault signal | field voltage < 150 mV or > 4 V, depending on lead disconnected |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Rated voltage | 19 ... 30 V DC |
Labeling | space for labeling at the front |
Accuracy | 0.1 % |
Control elements | DIP-switch |
Connection | terminals 5-, 7-, 6+, 8+ |
Current | 0 ... 10 mA |
Output/power supply | functional insulation, rated insulation voltage 50 V AC |
Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 |
Degree of protection | IEC 60529:2001 |
Ripple | within the supply tolerance |
Line fault detection | yes , at Pt100 |
Settling time | ≤ 5 ms |
Rated current | < 28 mA |
Protection against electrical shock | UL 61010-1:2012 |
Mass | approx. 100 g |
Buy Pepperl+Fuchs KCD2-RR2-Ex1.SP with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is an online electronic supply store. Our catalog includes pneumatic products, industrial sensors, controllers, low voltage equipment, drives, and motors, etc. Express delivery is available to all our clients. We sell only certified parts from European manufacturers. By cooperating with us, you will receive your orders on time. We respect your needs and are interested in their total satisfaction.