Pepperl+Fuchs KCD2-SCS-Ex2
SMART Transmitter Power Supply/SMART Current Driver
We ship to United States of America!
- 2-channel isolated barrier
- 24 V DC supply (Power Rail)
- Analog input (AI), Analog output (AO)
- Operates as transmitter power supply or current driver
- Housing width 12.5 mm
- Up to SIL 2 (SC 3) acc. to IEC/EN 61508
Item Number:
KCD2-SCS-Ex2
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Signal type | Analog input/analog output | |
Safety Integrity Level (SIL) | SIL 2 | |
Systematic capability (SC) | SC 3 | |
Connection | Power Rail or terminals 9+, 10- | |
Rated voltage | 19 ... 30 V DC | |
Ripple | max. 10 % | |
Rated current | max. 88 mA at 24 V | |
Power dissipation | max. 1.4 W | |
Power consumption | max. 2.1 W | |
Number of channels | 2 | |
Suitable field devices | 2-wire SMART transmitters | |
Signal | 0/4 ... 20 mA , limited to approx. 30 mA | |
Field circuit | terminals 1+, 2-, 3+, 4- | |
Available voltage | min. 15 V at 20 mA min. 18 V at 4 mA | |
Control circuit | terminals 5-, 6+; 7-, 8+ limited electrical values : max. 30 V , max. 2 A | |
Input voltage | Voltage across terminals 10 ... 30 V. If the current is supplied from a source > 24 V, series resistance of ?‰§ (V - 24)/0.02 Ω is needed, where V is the source voltage. The maximum value of the resistance is (V - 10)/0.02 Ω. (sink output) | |
Load | max. 350 Ω (source output) | |
Ripple | 20 mV eff | |
Number of channels | 2 | |
Suitable field devices | SMART I/P converters (positioner), on-site-displays | |
Signal | 0/4 ... 20 mA , limited to approx. 30 mA | |
Field circuit | terminals 1+, 2-, 3+, 4- | |
Load | max. 650 Ω | |
Voltage | min. 13 V at 20 mA | |
Ripple | 20 mV eff , on all signal terminals | |
Control circuit | terminals 5-, 6+; 7-, 8+ limited electrical values : max. 30 V , max. 2 A | |
Voltage drop | max. 6 V | |
Line fault detection | > 100 kΩ at max. 30 V, with field wiring open | |
Deviation | max. 20 ?µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage | |
Influence of ambient temperature | < 2 ?µA/K (-40 ... 70 ?°C (-40 ... 158 ?°F)) | |
Frequency range | field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) | |
Settling time | max. 200 ms | |
Rise time/fall time | max. 100 ms (10 ... 90 %) | |
Field circuit/control circuit | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Control circuit/control circuit | functional isolation, rated voltage: 50 V | |
Field circuit/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Control/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Display elements | LED | |
Factory setting | analog input with source output | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Electromagnetic compatibility | NE 21:2017 EN 61326-3-2:2018 | |
Degree of protection | IEC 60529:2001 | |
Protection against electrical shock | UL 61010-1:2019 | |
Ambient temperature | -40 ... 70 ?°C (-40 ... 158 ?°F) | |
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 115 g | |
Dimensions | 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
EU-type examination certificate | UL 22 ATEX 2786 X | |
Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
Output | Ex ia, Ex iaD | |
Voltage | 25.2 V | |
Current | 100 mA | |
Power | 630 mW | |
Internal capacitance | 1.05 nF | |
Internal inductance | 0 | |
Supply | ||
Maximum safe voltage | 250 V rms (Attention! The rated voltage can be lower.) | |
Input | ||
Maximum safe voltage | 250 V rms (Attention! The rated voltage can be lower.) | |
Certificate | UL 22 ATEX 2787 X | |
Marking | II 3G Ex ec IIC T4 Gc [device in zone 2] | |
Galvanic isolation | ||
Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Field circuit/power supply | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN IEC 60079-0:2018 , EN 60079-11:2012 , EN IEC 60079-7:2015+A1:2018 | |
UL approval | E106378 | |
Control drawing | 116-0490 (cULus) | |
IECEx approval | ||
IECEx certificate | IECEx ULD 22.0020X | |
IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc | |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. | |
ECLASS 13.0 | 27210120 | |
ECLASS 12.0 | 27210120 | |
ECLASS 11.0 | 27210120 | |
ECLASS 10.0.1 | 27210120 | |
ECLASS 9.0 | 27210120 | |
ECLASS 8.0 | 27210120 | |
ECLASS 5.1 | 27210120 | |
ETIM 9.0 | EC002653 | |
ETIM 8.0 | EC002653 | |
ETIM 7.0 | EC002653 | |
ETIM 6.0 | EC002653 | |
ETIM 5.0 | EC001485 | |
UNSPSC 12.1 | 32101514 |
Buy Pepperl+Fuchs KCD2-SCS-Ex2 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is an online electrical store. Our product range includes industrial sensors, motor control components, pneumatic automation, and many other automation equipment. You can receive your order in any country in the world. By providing you with minimum prices, you can save money. You don't need to pay in advance if you are our regular customer. We respect your needs and are interested in their total satisfaction.