Pepperl+Fuchs KCD2-SLD-Ex1.1065
Solenoid Driver

Pepperl+Fuchs KCD2-SLD-Ex1.1065
  • 1-channel isolated barrier
  • 24 V DC supply (bus or loop powered)
  • Output 65 mA at 10 V DC
  • Line fault transparency (LFT)
  • Test pulse immunity
  • Housing width 12.5 mm
  • Up to SIL 3 acc. to IEC 61508
Item Number: KCD2-SLD-Ex1.1065
368.96
-
+
Total price: 368.96
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Control elementsDIP-switch
Connection sidecontrol side
Degree of protectionIP20
EU-Type Examination CertificateEXA 17 ATEX 0002 X
Rated voltage19 ... 30 V DC
loop powered
Optional accessories- power feed module KFD2-EB2(.R4A.B)(.SP)
- universal power rail UPR-03(-M)(-S)
- profile rail K-DUCT-BU(-UPR-03)
Inrush current< 200 mA , 10 ms loop powered
Output/other circuitsbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Connectionterminals 1+, 2-
Signal levelloop powered
1-signal: 19 ... 30 V DC
0-signal: 0 ... 5 V DC
bus powered
1-signal: 15 ... 30 V DC (current limited at 5 mA)
0-signal: 0 ... 5 V DC
Electromagnetic compatibilityNE 21:2012 , EN 61326-3-2:2008
For further information see system description.
Signal typeDigital Output
Test pulse lengthmax. 2 ms from DO card
Internal resistor80 andOmega;
Voltagetyp. 10 V
UL approvalE106378
Connectionterminals 5+, 6- loop powered
Power Rail or terminals 9+, 10- bus powered
Power dissipation1.3 W at 24 V
Connectionterminals 5+, 6-
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Load150 andOmega;
Configurationvia DIP switches
Protection against electrical shockEN 61010-1:2010
Rated current0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card)
1-signal: 36 mA (minimum load current DO card)
Output II/power supplybasic insulation according to IEC/EN 61010-1, rated insulation voltage 32 Veff
Connection sidefield side
Current limit65 mA
Open loop voltagetyp. 16.4 V
Line fault detectionsignal at short-circuit RB < 25 andOmega;, lead breakage RB > 50 kandOmega; ; test current < 500 andmicro;A
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Currenttyp. 65 mA
Safety Integrity Level (SIL)SIL 3
Massapprox. 150 g
Loadnominal 0.05 ... 18 kandOmega;
Connectionscrew terminals
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Display elementsLEDs
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Degree of protectionIEC 60529:2013
Output IIfault signal
Input current80 mA at 24 V
Labelingspace for labeling at the front