Pepperl+Fuchs KCD2-SR-2
Switch Amplifier

Pepperl+Fuchs KCD2-SR-2
We ship to United States of America!
  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Housing width 12.5 mm
  • Up to SIL 2 acc. to IEC 61508
Item Number: KCD2-SR-2
128.09
-
+
Total price: 128.09
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +
Pulse/Pause ratiomin. 20 ms / min. 20 ms
Output IIsignal ; relay
Ripple 10 %
Degree of protectionIP20
Mechanical life107 switching cycles
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Connectionscrew terminals
Power consumption 600 mW
Input/power supplyreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Rated voltage19 ... 30 V DC
Open circuit voltage/short-circuit currentapprox. 10 V DC / approx. 8 mA
Output Isignal ; relay
Massapprox. 100 g
Line fault detectionbreakage I 0.1 mA , short-circuit I 6.5 mA
Output/power supplyreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Input/inputBasic insulation according to EN 50178, rated insulation voltage 300 Veff
Switching frequency 10 Hz
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Control elementsDIP-switch
Electromagnetic compatibilityNE 21:2006
Contact loading253 V AC/2 A/cos andphi; > 0.7; 126.5 V AC/4 A/cos andphi; > 0.7; 30 V DC/2 A resistive load
Labelingspace for labeling at the front
Display elementsLEDs
Degree of protectionIEC 60529
Ambient temperature-20 ... 60 ?°C (-4 ... 140 ?°F)
Connection sidecontrol side
ConnectionPower Rail or terminals 9+, 10-
Signal typeDigital Input
Connectionterminals 1+, 2-; 3+, 4-
Input/Outputreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Minimum switch current2 mA / 24 V DC
Safety Integrity Level (SIL)SIL 2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Connection sidefield side
Connectionterminals 5, 6; 7, 8
Configurationvia DIP switches
Rated current 30 mA
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Output/Outputreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Power dissipation 600 mW
Energized/De-energized delay 20 ms / 20 ms
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA

Buy Pepperl+Fuchs KCD2-SR-2 with the best possible price and delivery terms on eltra-trade.com

Discover a wide selection of industrial electrical products at eltra-trade.com. We specialize in sourcing and delivering the parts you need promptly. Our commitment to quality and competitive pricing sets us apart. Partner with us for reliable and efficient electrical supply solutions.

Comments

No comments yet

Write a comment