Pepperl+Fuchs KCD2-UT2-1
Universal Temperature Converter

Pepperl+Fuchs KCD2-UT2-1
We ship to United States of America!
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Thermocouple, RTD, potentiometer or voltage input
  • Current output 0/4 mA ... 20 mA
  • Sink or source mode
  • Configurable by PACTware
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
Item Number: KCD2-UT2-1
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +
Safety Integrity Level (SIL)SIL 2
Connectionscrew terminals
Thermocouplestype B, E, J, K, N, R, S, T (IEC 584-1: 1995)
type L (DIN 43710: 1985)
type TXK, TXKH, TXA (P8.585-2001)
Signal typeAnalog input
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Reaction timeworst case value (sensor breakage and/or sensor short circuit detection enabled)
mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s
Massapprox. 100 g
Programming interfaceprogramming socket
Ripplewithin the supply tolerance
Potentiometer0 ... 20 kandOmega; (2-wire connection), 0.8 ... 20 kandOmega; (3-wire connection)
Dimensions12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2
Input/Other circuitsbasic insulation according to IEC 61010-1, rated insulation voltage 300 Veff
Degree of protectionIEC 60529:2001
Degree of protectionIP20
Input resistance 1 MandOmega; (-100 ... 100 mV)
Output/supply, programming inputfunctional insulation, rated insulation voltage 50 V AC
There is no electrical isolation between the programming input and the supply.
The programming cable provides galvanic isolation so that ground loops are avoided.
Connectionterminals 1, 2, 3, 4
Rated voltage19 ... 30 V DC
Connection sidecontrol side
RTDtype Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)
type Cu10, Cu50, Cu100 (P50353-92)
type Ni100 (DIN 43760)
Electromagnetic compatibilityNE 21:2011
Power dissipation/power consumption 0.98 W / 0.98 W
Configurationvia PACTware
Display elementsLEDs
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Voltageselectable within the range -100 ... 100 mV
Connectionterminals 9+, 10- or power feed module/Power Rail
Labelingspace for labeling at the front
Connectionterminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+)
OutputAnalog current output
Connection sidefield side
Ambient temperature-20 ... 60 ?°C (-4 ... 140 ?°F)

Buy Pepperl+Fuchs KCD2-UT2-1 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. provides complete industrial automation solutions. With a wide selection of products and efficient delivery options, we meet your needs effectively. Our focus on quality and customer satisfaction distinguishes us. Experience our exceptional service and support for your automation needs.

Comments

No comments yet