Pepperl+Fuchs KCD2-UT2-1
Universal Temperature Converter
We ship to United States of America!
- 1-channel signal conditioner
- 24 V DC supply (Power Rail)
- Thermocouple, RTD, potentiometer or voltage input
- Current output 0/4 mA ... 20 mA
- Sink or source mode
- Configurable by PACTware
- Line fault (LFD) and sensor burnout detection
- Up to SIL 2 acc. to IEC 61508/IEC 61511
Item Number:
KCD2-UT2-1
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Safety Integrity Level (SIL) | SIL 2 |
Connection | screw terminals |
Thermocouples | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001) |
Signal type | Analog input |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Reaction time | worst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s |
Mass | approx. 100 g |
Programming interface | programming socket |
Ripple | within the supply tolerance |
Potentiometer | 0 ... 20 kandOmega; (2-wire connection), 0.8 ... 20 kandOmega; (3-wire connection) |
Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 |
Input/Other circuits | basic insulation according to IEC 61010-1, rated insulation voltage 300 Veff |
Degree of protection | IEC 60529:2001 |
Degree of protection | IP20 |
Input resistance | 1 MandOmega; (-100 ... 100 mV) |
Output/supply, programming input | functional insulation, rated insulation voltage 50 V AC There is no electrical isolation between the programming input and the supply. The programming cable provides galvanic isolation so that ground loops are avoided. |
Connection | terminals 1, 2, 3, 4 |
Rated voltage | 19 ... 30 V DC |
Connection side | control side |
RTD | type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760) |
Electromagnetic compatibility | NE 21:2011 |
Power dissipation/power consumption | 0.98 W / 0.98 W |
Configuration | via PACTware |
Display elements | LEDs |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Voltage | selectable within the range -100 ... 100 mV |
Connection | terminals 9+, 10- or power feed module/Power Rail |
Labeling | space for labeling at the front |
Connection | terminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+) |
Output | Analog current output |
Connection side | field side |
Ambient temperature | -20 ... 60 ?°C (-4 ... 140 ?°F) |
Buy Pepperl+Fuchs KCD2-UT2-1 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. provides complete industrial automation solutions. With a wide selection of products and efficient delivery options, we meet your needs effectively. Our focus on quality and customer satisfaction distinguishes us. Experience our exceptional service and support for your automation needs.
People also buy
Comments
No comments yet