Pepperl+Fuchs KCD2-UT2-Ex1
Universal Temperature Converter
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Thermocouple, RTD, potentiometer or voltage input
- Current output 0/4 mA ... 20 mA
- Sink or source mode
- Configurable by PACTware
- Line fault (LFD) and sensor burnout detection
- Up to SIL 2 acc. to IEC 61508/IEC 61511
- Overview +
- Comments +
The KCD2-UT2-Ex1 is an isolating barrier specifically designed for use with hazardous input signals. It ensures safe operation by providing galvanic isolation and is suitable for a variety of industrial applications. This device enhances safety and reliability in process automation by preventing interference and signal loss.
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Certificate | BASEEFA 13 ATEX 0103 X |
Mass | approx. 100 g |
Signal type | Analog input |
Output | Analog current output |
Degree of protection | IP20 |
EU-Type Examination Certificate | BASEEFA 13 ATEX 0102 X |
Connection | terminals 9+, 10- or power feed module/Power Rail |
Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 |
RTD | type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760) |
Programming interface | programming socket |
IECEx approval | IECEx BAS 13.0057X |
Connection side | field side |
Electromagnetic compatibility | NE 21:2011 |
Configuration | via PACTware |
Degree of protection | IEC 60529:2001 |
Reaction time | worst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s |
Input resistance | 1 MandOmega; (-100 ... 100 mV) |
Ambient temperature | -20 ... 60 ?°C (-4 ... 140 ?°F) |
Connection side | control side |
Ripple | within the supply tolerance |
Connection | screw terminals |
Display elements | LEDs |
Thermocouples | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001) |
Rated voltage | 19 ... 30 V DC |
Labeling | space for labeling at the front |
Connection | terminals 1, 2, 3, 4 |
Connection | terminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+) |
Voltage | selectable within the range -100 ... 100 mV |
Inputs | terminals 1, 2, 3, 4 |
Output/supply, programming input | functional insulation, rated insulation voltage 50 V AC There is no electrical isolation between the programming input and the supply. The programming cable provides galvanic isolation so that ground loops are avoided. |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Protection against electrical shock | UL 61010-1:2004 |
Potentiometer | 0 ... 20 kandOmega; (2-wire connection), 0.8 ... 20 kandOmega; (3-wire connection) |
Safety Integrity Level (SIL) | SIL 2 |
Power dissipation/power consumption | 0.98 W / 0.98 W |
Buy Pepperl+Fuchs KCD2-UT2-Ex1 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. delivers top-quality industrial control products. Our extensive inventory ensures you find the parts you need, with worldwide delivery options. We offer competitive prices and personalized service. Get in touch today to see how we can support your business effectively and efficiently.
Comments
No comments yet