Pepperl+Fuchs KCD2-UT2-Ex1
Universal Temperature Converter

- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Thermocouple, RTD, potentiometer or voltage input
- Current output 0/4 mA ... 20 mA
- Sink or source mode
- Configurable by PACTware
- Line fault (LFD) and sensor burnout detection
- Up to SIL 2 acc. to IEC 61508/IEC 61511

Item Number:
KCD2-UT2-Ex1
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Datasheet
- Alternative numbers
- Comments
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Certificate | BASEEFA 13 ATEX 0103 X |
Mass | approx. 100 g |
Signal type | Analog input |
Output | Analog current output |
Degree of protection | IP20 |
EU-Type Examination Certificate | BASEEFA 13 ATEX 0102 X |
Connection | terminals 9+, 10- or power feed module/Power Rail |
Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 |
RTD | type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760) |
Programming interface | programming socket |
IECEx approval | IECEx BAS 13.0057X |
Connection side | field side |
Electromagnetic compatibility | NE 21:2011 |
Configuration | via PACTware |
Degree of protection | IEC 60529:2001 |
Reaction time | worst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s |
Input resistance | 1 MandOmega; (-100 ... 100 mV) |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Connection side | control side |
Ripple | within the supply tolerance |
Connection | screw terminals |
Display elements | LEDs |
Thermocouples | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001) |
Rated voltage | 19 ... 30 V DC |
Labeling | space for labeling at the front |
Connection | terminals 1, 2, 3, 4 |
Connection | terminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+) |
Voltage | selectable within the range -100 ... 100 mV |
Inputs | terminals 1, 2, 3, 4 |
Output/supply, programming input | functional insulation, rated insulation voltage 50 V AC There is no electrical isolation between the programming input and the supply. The programming cable provides galvanic isolation so that ground loops are avoided. |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Protection against electrical shock | UL 61010-1:2004 |
Potentiometer | 0 ... 20 kandOmega; (2-wire connection), 0.8 ... 20 kandOmega; (3-wire connection) |
Safety Integrity Level (SIL) | SIL 2 |
Power dissipation/power consumption | 0.98 W / 0.98 W |
People also buy
Comments
No comments yet