Pepperl+Fuchs KE5D2-6H/2R-S
Safety Monitor

Pepperl+Fuchs KE5D2-6H/2R-S
  • 24 V AC/DC supply
  • (6) Monitored inputs
  • DIN rail mountable
  • Dual output relay contacts
  • Internal relay monitoring
  • Removable screw terminals
Item Number: KE5D2-6H/2R-S
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
LED greenpower
UL approvalUL 508
Input type(6) dedicated input devices for 50FY41-.. series
Power consumption< 12 W
Input voltage12 V DC , (2 channel, sink/source)
Massapprox. 545 g
MountingDIN mounting rail
Output I2 relay outputs , NO Contact
Response time20 ms (switch open to contact open)
Switching stateLED red flashing: fault signal
LED red/greenrelay : ( 2 ) red , ( 2 ) green
Rated voltage24 V AC/V DC ( for AC, 45 ... 62 Hz )
Rated current< 0 . 5 A
Ambient temperature-20 ... 50 В°C (-4 ... 122 В°F)
Connectionscrew connection, max. 2.5 mm2
Degree of protectionIP20
Time delay before availability3 s
Current5 mA to 5 A (NO contact)
LED redsensor status (one per channel/two per input)
UL File NumberE179102

Comments

No comments yet