Pepperl+Fuchs KFA5-SR2-Ex1.W.LB
Switch Amplifier

Pepperl+Fuchs KFA5-SR2-Ex1.W.LB
We ship to United States of America!
  • 1-channel isolated barrier
  • 115 V AC supply
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Fault relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
Item Number: KFA5-SR2-Ex1.W.LB
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +

Energized/De-energized delayapprox. 20 ms / approx. 20 ms

Mechanical life107 switching cycles
Labelingspace for labeling at the front
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Connectionoutput I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Rated valuesacc. to EN 60947-5-6 (NAMUR)
EU-Type Examination CertificatePTB 00 ATEX 2081
Connectionscrew terminals
Signal typeDigital Input
Power consumptionmax. 1.3 W
Pulse/Pause ratiomin. 20 ms / min. 20 ms
Output IIsignal or error message ; relay
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Output Isignal ; relay
Massapprox. 150 g
IECEx approvalIECEx PTB 11.0031
Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Degree of protectionIEC 60529:2001
Connection sidefield side
Electromagnetic compatibilityNE 21:2006
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Contact loading253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
Degree of protectionIP20
Control elementsDIP-switch
Rated voltage103.5 ... 126 V AC , 45 ... 65 Hz
Connectionterminals 1+, 2+, 3-
Connection sidecontrol side
Power dissipation1.2 W
Ambient temperature-20 ... 60 ?°C (-4 ... 140 ?°F)
Line fault detectionbreakage I ≤ 0.1 mA , short-circuit I > 6 mA
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Connectionterminals 14, 15
Output/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
InputEN 60947-5-6:2000
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Open circuit voltage/short-circuit currentapprox. 8 V DC / approx. 8 mA
Safety Integrity Level (SIL)SIL 2
Display elementsLEDs
Configurationvia DIP switches
Switching frequency≤ 10 Hz

Buy Pepperl+Fuchs KFA5-SR2-Ex1.W.LB with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com offers a comprehensive range of industrial electrical products. We specialize in sourcing and delivering hard-to-find parts promptly. Our commitment to quality and competitive pricing makes us a preferred supplier. Partner with us for reliable and efficient electrical supply solutions.

Comments

No comments yet

Write a comment