Pepperl+Fuchs KFA6-ER-1.6
Conductivity Switch Amplifier
We ship to United States of America!
- 1-channel signal conditioner
- 230 V AC supply
- Level sensing input
- Adjustable range 5 k Omega- ... 150 k Omega-
- Relay contact output
- Minimum/maximum control
Item Number:
KFA6-ER-1.6
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Response sensitivity | 5 ... 150 kandOmega; , adjustable via potentiometer (20 turns) |
Power consumption | approx. 0.8 W |
Connection | terminals 1 (mass), 2 (min), 3 (max) |
Contact loading | 253 V AC/2 A/cos andphi; > 0.7; 40 V DC/2 A resistive load |
Labeling | space for labeling at the front |
Galvanic isolation | EN 50178:1997 |
Connection | screw terminals , max. 2.5 mm2 |
Signal type | Digital Input |
Output | 1 changeover contact |
Mass | approx. 110 g |
Connection side | control side |
Degree of protection | IEC 60529:2001 |
Connection side | field side |
Energized/De-energized delay | approx. 1 s / approx. 1 s |
Connection | terminals 7, 8, 9 |
Rated voltage | 207 ... 253 V AC, 45 ... 65 Hz |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Output/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Control elements | DIP-switch potentiometer |
Insulation coordination | EN 50178:1997 |
Control input | min./max. control system: terminals 1, 2, 3 on/off control system: terminals 1, 3 |
Ambient temperature | -20 ... 60 ?°C (-4 ... 140 ?°F) |
Degree of protection | IP20 |
Display elements | LEDs |
Input/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Control elements | switch S1 Position I open circuit current: In the open circuit current principle, the relay becomes active when the limit is reached. Position II closed circuit current: In closed circuit current principle, the relay is activated when power is applied. The relay is deactivated when the limit is reached. |
Dimensions | 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) , housing type B1 |
Open circuit voltage/short-circuit current | approx. 10 V AC (approx. 1 Hz) / approx. 5 mA |
Electromagnetic compatibility | NE 21:2006 |
Input/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Connection | terminals 11 (L1), 12 (N) |
Configuration | via DIP switches via potentiometer |