Pepperl+Fuchs KFD2-CRG2-1.D
Transmitter Power Supply

Pepperl+Fuchs KFD2-CRG2-1.D
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Input 2-wire and 3-wire transmitters and 2-wire current sources
  • Output 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Adjustable energized/de-energized delay
  • Programmable high/low alarm
  • Linearization function (max 20 points)
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
Item Number: KFD2-CRG2-1.D
377.00
-
+
Total price: 377.00
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3
Interface/power supply and collective errorfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Power dissipation2 W
Connectionterminals 1, 2, 3
Optional accessories- power feed module KFD2-EB2(.R4A.B)(.SP)
- universal power rail UPR-03(-M)(-S)
- profile rail K-DUCT-GY(-UPR-03)
- FDT framework PACTware 4.1
- device type manager DTM Interface Technology
- adapter K-ADP-USB
Safety Integrity Level (SIL)SIL 2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Labelingspace for labeling at the front
Mass300 g
Connection sidefield side
Degree of protectionIEC 60529:2001
Signal typeAnalog input
Energized/De-energized delay0 ... 250 s , adjustable
Output I, IIsignal, relay
UL approvalE223772
Output IIISignal, analog
Output signal0 ... 20 mA or 4 ... 20 mA
Configurationvia operating buttons
via PACTware
Degree of protectionIP20
Power consumption2.5 W
Rated currentapprox. 130 mA
Connection sidecontrol side
Programming interfaceprogramming socket
Control elementsControl panel
Connectionoutput I: terminals 10, 11, 12
output II: terminals 16, 17, 18
Output: analog terminals 8+, 7-
Display elementsLEDs , display
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Rated voltage20 ... 30 V DC
Output III/power supply and collective errorfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Electromagnetic compatibilityNE 21:2006
ConnectionPower Rail or terminals 23+, 24-
Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/Other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Connectionscrew terminals

Comments

No comments yet