Pepperl+Fuchs KFD2-SRA-Ex4
Switch Amplifier

Pepperl+Fuchs KFD2-SRA-Ex4
We ship to United States of America!
  • 4-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • 50 % less wiring, 2:1 technology
  • Relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
Item Number: KFD2-SRA-Ex4
342.11
-
+
Total price: 342.11
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Ripple10 %

Rated valuesacc. to EN 60947-5-6 (NAMUR), see system description for electrical data
Line fault detectionbreakage I 0.15 mA , short-circuit I > 6 mA
Optional accessories- power feed module KFD2-EB2(.R4A.B)(.SP)
- universal power rail UPR-03(-M)(-S)
- profile rail K-DUCT-BU(-UPR-03)
- terminal module F-KD-Ex2
- terminal module F-KDR-Ex2
Display elementsLEDs
Power dissipation1.2 W
Mechanical life5 x 106 switching cycles
Control elementsDIP-switch
InputEN 60947-5-6:2000
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Signal typeDigital Input
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Energized/De-energized delayapprox. 30 ms / approx. 30 ms
Connectionoutput I: terminals 7, 8 ; output II: terminals 8, 9 ; output III: terminals 10, 11 ; output IV: terminals 11, 12
Electromagnetic compatibilityNE 21:2006
Output/Outputbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Degree of protectionIEC 60529:2001
Rated current45 ... 70 mA
ConnectionPower Rail or terminals 14+, 15-
Connection sidecontrol side
Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Degree of protectionIP20
Massapprox. 150 g
Open circuit voltage/short-circuit currentapprox. 8 V DC / approx. 8 mA
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I ... IVSignal I ... Signal IV ; relay
Ambient temperature-20 ... 60 ?°C (-4 ... 140 ?°F)
Connection sidefield side
Switching frequency10 Hz (non-AC operation) 3 Hz (AC operation)
Contact loading253 V AC/2 A /cos andphi; > 0.7; 40 V DC/2 A resistive load;
Connectionscrew terminals
Configurationvia DIP switches
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Pulse/Pause ratiomin. 35 ms / min. 35 ms (non-AC operation) min. 70 ms / min. 70 ms (AC operation)
Collective error messagePower Rail
IECEx approvalIECEx TUN 04.0003
Rated voltage19 ... 30 V DC
Labelingspace for labeling at the front
EU-Type Examination CertificateZELM 99 ATEX 0009
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Connectionterminals 1-, 2+, 3-; 4-, 5+, 6-

Buy Pepperl+Fuchs KFD2-SRA-Ex4 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is a global leader in industrial automation supply. Our extensive catalog includes top brands, with worldwide delivery and competitive pricing. We focus on customer satisfaction and reliability. Experience our exceptional service and support for all your automation needs.

Comments

No comments yet

Write a comment