Pepperl+Fuchs KFD2-UT2-2
Universal Temperature Converter

Pepperl+Fuchs KFD2-UT2-2
  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Thermocouple, RTD, potentiometer or voltage input
  • Usable as signal splitter (1 input and 2 outputs)
  • Current output 0/4 mA ... 20 mA
  • Sink or source mode
  • Configurable by PACTware
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
Item Number: KFD2-UT2-2
437.00
-
+
Total price: 437.00
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
RTDtype Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)
type Cu10, Cu50, Cu100 (P50353-92)
type Ni100 (DIN 43760)
Connectionterminals 1, 2, 3; 4, 5, 6
Degree of protectionIP20
Configurationvia PACTware
Connectionterminals 14+, 15- or power feed module/Power Rail
Ripplewithin the supply tolerance
Voltageselectable within the range -100 ... 100 mV
Safety Integrity Level (SIL)SIL 2
Degree of protectionIEC 60529:2001
Connection sidecontrol side
Massapprox. 130 g
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Output/supply, programming inputfunctional insulation, rated insulation voltage 50 V AC
There is no electrical isolation between the programming input and the supply.
The programming cable provides galvanic isolation so that ground loops are avoided.
Signal typeAnalog input
Programming interfaceprogramming socket
Output I, IIAnalog current output
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Electromagnetic compatibilityNE 21:2006
Connectionscrew terminals
Rated voltage20 ... 30 V DC
Input resistance 1 MandOmega; (-100 ... 100 mV)
Labelingspace for labeling at the front
Reaction timeworst case value (sensor breakage and/or sensor short circuit detection enabled)
mV: 1.2 s, thermocouples with CJC: 1.4 s, thermocouples with fixed ref. temp: 1.4 s, 3- or 4-wire RTD: 1.1 s, 2-wire RTD: 920 ms, Potentiometer: 3-wire connection 2.8 s, 2-wire connection 2.25 s
Input/Other circuitsbasic insulation according to IEC 61010-1, rated insulation voltage 300 Veff
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Power dissipation/power consumption 1.53 W / 1.53 W
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Connection sidefield side
Potentiometer0 ... 20 kandOmega; (2-wire connection), 0.8 ... 20 kandOmega; (3-wire connection)
Connectionoutput I: terminal 7: source (-), sink (+), terminal 8: source (+), terminal 9: sink(-)
output II: terminal 10: source (-), sink (+), terminal 11: source (+), terminal 12: sink(-)
Display elementsLEDs
Thermocouplestype B, E, J, K, N, R, S, T (IEC 584-1: 1995)
type L (DIN 43710: 1985)
type TXK, TXKH, TXA (P8.585-2001)

Comments

No comments yet

Write a comment