Pepperl+Fuchs KFD2-UT2-Ex2
Universal Temperature Converter

Pepperl+Fuchs KFD2-UT2-Ex2
We ship to United States of America!
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Thermocouple, RTD, potentiometer or voltage input
  • Usable as signal splitter (1 input and 2 outputs)
  • Current output 0/4 mA ... 20 mA
  • Sink or source mode
  • Configurable by PACTware
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
Item Number: KFD2-UT2-Ex2
792.00
-
+
Total price: 792.00
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Output I, IIAnalog current output
Degree of protectionIEC 60529:2001
Massapprox. 130 g
Connectionterminals 14+, 15- or power feed module/Power Rail
Connectionterminals 1, 2, 3; 4, 5, 6
Rated voltage20 ... 30 V DC
Display elementsLEDs
Connectionscrew terminals
Connection sidefield side
Connectionoutput I: terminal 7: source (-), sink (+), terminal 8: source (+), terminal 9: sink(-)
output II: terminal 10: source (-), sink (+), terminal 11: source (+), terminal 12: sink(-)
CertificateTГњV 02 ATEX 1797 X
Safety Integrity Level (SIL)SIL 2
Signal typeAnalog input
Programming interfaceprogramming socket
Electromagnetic compatibilityNE 21:2006
Input resistance 1 MandOmega; (-100 ... 100 mV)
Degree of protectionIP20
Reaction timeworst case value (sensor breakage and/or sensor short circuit detection enabled)
mV: 1.2 s, thermocouples with CJC: 1.4 s, thermocouples with fixed ref. temp: 1.4 s, 3- or 4-wire RTD: 1.1 s, 2-wire RTD: 920 ms, Potentiometer: 3-wire connection 2.8 s, 2-wire connection 2.25 s
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Connection sidecontrol side
Configurationvia PACTware
EU-Type Examination CertificateCESI 04 ATEX 143
Voltageselectable within the range -100 ... 100 mV
Ripplewithin the supply tolerance
Power dissipation/power consumption 1.53 W / 1.53 W
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Labelingspace for labeling at the front
Potentiometer0 ... 20 kandOmega; (2-wire connection), 0.8 ... 20 kandOmega; (3-wire connection)
RTDtype Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)
type Cu10, Cu50, Cu100 (P50353-92)
type Ni100 (DIN 43760)
Thermocouplestype B, E, J, K, N, R, S, T (IEC 584-1: 1995)
type L (DIN 43710: 1985)
type TXK, TXKH, TXA (P8.585-2001)

Buy Pepperl+Fuchs KFD2-UT2-Ex2 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is an electrical equipment shop. We have the status of the official representative of many European brands. We deliver to any country in the world. Our company is not an official distributor of all brands, but we can offer you competitive prices for all items in our catalog. We provide accurate delivery time information at the very beginning. We are the partner who can trust.