Pepperl+Fuchs KFD2-WAC2-Ex1.D
Strain Gauge Converter

Pepperl+Fuchs KFD2-WAC2-Ex1.D
We ship to United States of America!
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Strain gauge input (full or half bridge)
  • Output 0 mA ... ?± 20 mA or 0 V ... ?± 10 V
  • 2 relay contact outputs
  • Programmable high/low alarm
  • Configurable by PACTware or keypad
  • RS-485 interface
  • Line fault detection (LFD)
Item Number: KFD2-WAC2-Ex1.D
799.58
-
+
Total price: 799.58
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

This model is an analog input isolator designed for HART communication protocols. The KFD2-WAC2-Ex1.D allows for simultaneous transmission of both analog and digital signals, ensuring that both control and diagnostic data are reliably communicated. Its design is optimized for use in hazardous areas, enhancing safety and operational efficiency.

Datasheet:

Reaction time300 ... 850 ms
Output I, IIRelay output
ConnectionInput I: terminals 1+, 2-; Input II: terminals 13+, 14-; Input III: terminals 15+, 14-
Output I, II against eachotherreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Electromagnetic compatibilityNE 21:2006
Labelingspace for labeling at the front
Input I/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Line fault detectiondownscale -21.5 mA (-10.75 V) or 2 mA (1 V), upscale 21.5 mA (10.75 V)
Collective error messagePower Rail
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
TypeRS-485
IECEx approvalIECEx TUN 06.0005
Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3
Degree of protectionIP20
Massapprox. 250 g
EU-Type Examination CertificateT??V 04 ATEX 2531
Ambient temperature-20 ... 60 ?°C (-4 ... 140 ?°F)
Output IIIterminals 7-, 8+, 9- non-intrinsically safe
Programming interfaceprogramming socket
Output III/Programming socketnot available
Output IIIAnalog output
Connection sidefield side
Input ISignal, analog
Rated voltage20 ... 35 V DC
UL approvalE223772
Lead resistancemax. 25 andOmega; per line
Ripplewithin the supply tolerance
ConnectionPower Rail or terminals 23+, 24-
Display elementsLEDs , display
Programmable Tare0 ... 500 % of span
Connectionscrew terminals
Connectionterminals 1+, 2-, 3+, 4-, 5+, 6-
Output III/Input II, IIInot available
Sensor supply1 ... 5 V
Signal typeAnalog input
Input Iterminals 1+, 2- Ex ia IIC, Ex iaD
ConnectionPower Rail or terminals 19+, 20 GND, 21-
Input II and IIIterminals 13+, 14-; 15+, 14- non-intrinsically safe
Other circuits from each otherfunctional insulation, rated insulation voltage 50 Veff
Output I, IIterminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
InterfaceRS 485 programming jack
Input II, IIItare adjustment, calibration and zero
ConnectionOutput I: terminals 10, 11, 12; Output II: terminals 16, 17, 18; Output III: terminals 7-, 8+, 9-
Configurationvia operating buttons
via PACTware
Control elementsControl panel
Connection sidecontrol side
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Degree of protectionIEC 60529:2001
Power consumptionmax. 3 W
SupplyPower Rail or terminals 23+, 24- non-intrinsically safe

Buy Pepperl+Fuchs KFD2-WAC2-Ex1.D with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is an electrical supply store online. We provide an enhanced product catalog for our clients. Rush shipping is available to any country. We supply only certified products from European brands. We always strive to correspond with the delivery times. Our company has a very well-established supply chain so we always provide the equipment on time and without delay.