Pepperl+Fuchs KFU8-UFT-2.D

Frequency Converter with Direction and Synchronization Monitor
Pepperl+Fuchs KFU8-UFT-2.D
458.88
One click request

Connectionoutput I: terminals 10, 11, 12
output II: terminals 16, 17, 18
output III: terminals 19+, 20-
output IV: terminals 21+, 20-
output V: terminals 7-, 8+

Mass300 g
Rated currentapprox. 130 mA
Signal typeDigital Input
Connection sidecontrol side
Connection sidefield side
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Connectionscrew terminals
Power dissipation2.2 W / 3.5 VA
InputEN 60947-5-6:2000
Connectioninput I: terminals 1+, 3-
input II: terminals 4+, 6-
input III: terminals 13+, 14- (control input 1)
input IV: terminals 15+, 14- (control input 2)
Power consumption2.5 W / 4 VA
Configurationvia operating buttons
via PACTware
Input III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3
Degree of protectionIP20
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Control elementsControl panel
Output III, IV/Vbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Labelingspace for labeling at the front
Output V/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III, IV/input III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Interface/output III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Display elementsLEDs , display
Input I, II2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
Programming interfaceprogramming socket
Input I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output Vanalog
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Output III and IVsignal , electronic output, passive
Degree of protectionIEC 60529:2001
Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, IVreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Connectionterminals 23, 24
Electromagnetic compatibilityNE 21:2006
Output I, IIsignal, relay
Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz
in international format without spaces