Degree of protectionIP20
Degree of protection | IEC 60529 |
Rated voltage | max. 35 V SELV/PELV |
LED PWR | green: Power on |
Ethernet/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
Certificate | TГњV 14 ATEX 115980 X |
Mass | 500 g |
Rated voltage | 19.2 ... 35 V DC SELV/PELV |
Connection type | RJ-45 socket, 8-pin |
Electromagnetic compatibility | NE 21 |
Vibration resistance | 1 g , 10 ... 150 Hz |
Fault signal | buzzer on |
Ethernet/Supply | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
Fieldbus type | FOUNDATION Fieldbus |
Shock resistance | EN 60068-2-27 |
Implementation | resource block function block transducer block |
Ambient temperature | -40 ... 60 В°C (-40 ... 140 В°F) hazardous area -40 ... 70 В°C (-40 ... 158 В°F) safe area horizontal DIN rail mounting |
All circuits/FE | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
Services | ICMP , DHCP , AutoIP , HTTP |
Number of Diagnostic Modules/Channel | 31 Using Ethernet Interface , 8 Using Fieldbus Interface |
Protocol | TCP/IP and UDP/IP |
Polarity | polarity-sensitive |
Design / Mounting | Motherboard based |
Cable length/Channel | 30 m |
Connection | only for the connection to protected circuits |
Relative humidity | < 95 % non-condensing |
Number of Diagnostic Bus Channels | 2 |
Housing depth | see dimensions |
Vibration resistance | EN 60068-2-6 |
Rated voltage | 9 ... 35 V SELV/PELV |
Rated current | 0 mA |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Diagnostic Bus/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
Termination | integrated |
ITK version | 6 |
Firmware update | Ethernet |
Housing height | see dimensions |
LINK/ACT | yellow |
Physical layer profile | profile type 114 |
Shock resistance | 5 g 11 ms |
Rated current | 210 ... 120 mA |
Housing material | Polycarbonate |
Pollution degree | max. 2, according to IEC 60664 |
Rated voltage | max. 35 V |
CH1, CH2 | yellow: diagnostic bus activity |
Power dissipation | max. 4.2 W |
Fieldbus standard | IEC 61158-2 |
Housing width | see dimensions |
Fieldbus/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
IECEx approval | IECEx TUN 14.0003X |
Climatic conditions | DIN IEC 721 |
Ethernet | IEEE 802.3 |
Mounting | DIN rail mounting |
Galvanic isolation | IEC 62103 |
Transfer rate | 100 MBit/s |
LED ERR | red: Hardware fault |
Output I, II/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 250 Veff |
Port | 100 BASE-TX |