Pepperl+Fuchs LA28/LK28-Z-F1/31/116
Thru-beam sensor
- Universal series with highly versatile fields of use
- Resistant against noise: reliable operation under all conditions
- Highly visible LED as alignment aid in receiver optics
- Programmable time function GAN, GAB, IAB as well as GAN-IAB and GAN-GAB as double function
- Version with red light
- Version with relay output
Item Number:
LA28/LK28-Z-F1/31/116
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Timer function | ON delay (GAN), OFF delay (GAB), one shot (IAB), ON delay-OFF delay (GAN-GAB), programmable adjustment range 0.1 ...10 s |
Housing height | 88 mm |
EAC conformity | TR CU 020/2011 TR CU 004/2011 |
Storage temperature | -40 ... 75 В°C (-40 ... 167 В°F) |
Receiver | LK28-Z-F1/31/116 |
Alignment aid | LED red (in receiver lens) illuminated constantly: beam is interrupted, flashes: reaching switching point, off: sufficient stability control |
Connection | terminal compartment with 8 spring-loaded terminals for wire cross section 0.5 ... 1.5 mm2 , Insulation stripping 7.5 ... 8.5 mm , M16 x 1.5 cable gland |
Function indicator | LED yellow: 1. LED lit constantly: signal > 2 x switching point (function reserve) 2. LED flashes: signal between 1 x switching point and 2 x switching point 3. LED off: signal < switching point |
Switching type | light/dark on, switchable . (selectable, light/dark switching is only activated if the receiver has 'dark on' selected.) |
Switching power | DC: max. 50 W AC: max. 500 VA |
Emitter | LA28-F1/116 |
Housing depth | 65.5 mm |
Protection class | II, rated insulation voltage 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140. Caution! The protection class 2 is only valid when the terminal compartment is closed. |
Diameter of the light spot | approx. 1.3 m at 65 m |
Operating voltage | 12 ... 240 V AC/DC |
Degree of protection | IP67 |
Control elements | sensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-on/dark-on changeover switch |
Response time | 20 ms |
Switching frequency | 25 Hz |
Ambient temperature | -40 ... 60 В°C (-40 ... 140 В°F) |
Switching current | max. 2 A |
Product standard | EN 60947-5-2 |
Ambient light limit | 50000 Lux |
MTTFd | 490 a |
CCC approval | Certified by China Compulsory Certification (CCC) |
Diagnostic Coverage (DC) | 0 % |
Switching voltage | max. 250 V AC/DC |
Mission Time (TM) | 20 a |
Threshold detection range | 90 m |
Housing width | 25.8 mm |
UL approval | cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. |
Signal output | Relay, 1 alternator |
Mass | 200 g (emitter and receiver) |
Power consumption | 3.5 VA |
Operation indicator | LED green |
Light source | LED |
Light type | modulated visible red light |
Angle of divergence | Emitter 1.2В°, Receiver 5В° |
Transmitter frequency | F1 = 25 kHz |
Effective detection range | 0 ... 65 m |