Pepperl+Fuchs LB3005A2

HART Transmitter Power Supply, Input Isolator
Pepperl+Fuchs LB3005A2
Price on Request
One click request
4-wire transmitter (powered externally):Supply circuit: channel I 1+, 4-, channel II 5+, 8-, channel III 9+, 12-, channel IV 13+, 16-3-wire transmitter:Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-Supply circuit: channel I 1+, 2-, channel II 5+, 6-, channel III 9+, 10-, channel IV 13+, 14-
ATEX approvalBVS 12 ATEX E 105 X
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Power consumption2.7 W
Conversion timemax. 100 ms
Massapprox. 150 g
Connection2-wire transmitter (HART):
Refresh time100 ms
Rated voltage12 V DC , only in connection with the power supplies LB9***
Transmitter supply voltagemin. 15 V at 20 mA ; 21.5 V at 4 mA
Connectionbackplane bus
Power dissipation1.5 W
Occupied slots2
Relative humidity95 % non-condensing
Connectionbackplane bus
HART secondary variableno
Input resistance15 andOmega;
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistanceEN 60068-2-6:2008
Codingoptional mechanical coding via front socket
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Environmental testEN 60068-2-14:2009
IECEx approvalBVS 12.0055X
Relative humidityEN 60068-2-78:2001
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
Degree of protectionIP20 when mounted on backplane
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Resolution12 Bit (0 ... 26 mA)
Dimensions32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Shock resistanceEN 60068-2-27:2009
Number of channels4
LED indicationPower LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (1-4) red: line fault (lead breakage or short circuit)
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F) , 70 В°C (non-Ex)
CertificateBVS 12 ATEX E 105 X
Degree of protectionIEC 60529:2000
Interfacemanufacturer-specific bus to standard com unit
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure.
HART communicationyes
Damaging gasEN 60068-2-42:2003
Electromagnetic compatibilityNE 21:2007
in international format without spaces