Pepperl+Fuchs LB3006A
HART Transmitter Power Supply

Pepperl+Fuchs LB3006A
We ship to United States of America!
  • 4-channel
  • Power supply for 2-wire transmitters with 4 mA ... 20 mA
  • Installation in Zone 2 or safe area
  • Supply circuit 21.5 V (4 mA)
  • HART communication via field bus or service bus
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD): one LED per channel
  • Permanently self-monitoring
  • Module can be exchanged under voltage
Item Number: LB3006A
1018.11
-
+
Total price: 1018.11
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Electromagnetic compatibilityNE 21:2007

Rated voltage12 V DC , only in connection with the power supplies LB9***
Shock resistanceEN 60068-2-27:2009
ATEX approvalBVS 12 ATEX E 115 X
Relative humidity95 % non-condensing
Damaging gasEN 60068-2-42:2003
Connectionbackplane bus
Relative humidityEN 60068-2-78:2001
Transmitter supply voltagemin. 15 V at 20 mA ; 21.5 V at 4 mA
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F) , 70 В°C (non-Ex)
Power consumption2.7 W
Massapprox. 90 g
Occupied slots1
Dimensions16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)
Connection2-wire transmitter (HART):
supply circuit: channel I 1+, 2-, channel II 3+, 4-, channel III 5+, 6-, channel IV 7+, 8-
Input resistance15 andOmega;
Degree of protectionIEC 60529:2000
IECEx approvalBVS 11.0068X
LED indicationPower LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (1-4) red: line fault (lead breakage or short circuit)
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure.
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Number of channels4
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Connectionbackplane bus
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
CertificateBVS 12 ATEX E 115 X
Codingoptional mechanical coding via front socket
Resolution12 Bit (0 ... 26 mA)
Environmental testEN 60068-2-14:2009
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
Vibration resistanceEN 60068-2-6:2008
Power dissipation1.5 W
Conversion timemax. 100 ms
HART communicationyes
Interfacemanufacturer-specific bus to standard com unit
Refresh time100 ms
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
HART secondary variableno
Degree of protectionIP20 when mounted on backplane

Buy Pepperl+Fuchs LB3006A with the best possible price and delivery terms on eltra-trade.com