Pepperl+Fuchs LB3106A
HART Transmitter Power Supply

Pepperl+Fuchs LB3106A
We ship to United States of America!
  • 4-channel
  • Inputs Ex ia
  • Mounting in Zone 2, Class I/Div.2 or in the safe area
  • Power supply for 2-wire transmitters with 4 mA ... 20 mA
  • Supply circuit 15 V (20 mA)
  • HART communication via field bus or service bus
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD): one LED per channel
  • Permanently self-monitoring
  • Module can be exchanged under voltage
Item Number: LB3106A
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +
Connectionbackplane bus
Electromagnetic compatibilityNE 21:2007
ATEX approvalBVS 11 ATEX E 116X
Occupied slots1
Relative humidity95 % non-condensing
Vibration resistanceEN 60068-2-6:2008
Environmental testEN 60068-2-14:2009
Storage temperature-25 ... 85 ?°C (-13 ... 185 ?°F)
Dimensions16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)
Shock resistanceEN 60068-2-27:2009
Number of channels4
Connectionbackplane bus
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Conversion timemax. 100 ms
Transmitter supply voltagemin. 15 V at 20 mA ; 21.5 V at 4 mA
Rated voltage12 V DC , only in connection with the power supplies LB9***
Connection2-wire transmitter (HART):
supply circuit: channel I 1+, 2-, channel II 3+, 4-, channel III 5+, 6-, channel IV 7+, 8-
Resolution12 Bit (0 ... 26 mA)
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
IECEx approvalBVS 11.0068X
UL approvalE106378
Power consumption2.7 W
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Ambient temperature-20 ... 60 ?°C (-4 ... 140 ?°F)
EU-Type Examination CertificateBVS 11 ATEX E 116 X
HART communicationyes
Relative humidityEN 60068-2-78:2001
Degree of protectionIEC 60529:2000
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Refresh time100 ms
Damaging gasEN 60068-2-42:2003
Massapprox. 90 g
Interfacemanufacturer-specific bus to standard com unit
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
HART secondary variableno
Power dissipation1.5 W
Degree of protectionIP20 when mounted on backplane
Input resistance15 andOmega;
LED indicationPower LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (1-4) red: line fault (lead breakage or short circuit)
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ?± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ?± 1 mm/0.7 g; 90 minutes at each resonance
Codingoptional mechanical coding via front socket

Buy Pepperl+Fuchs LB3106A with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. delivers top-quality industrial control products. Our extensive inventory ensures you find the parts you need, with worldwide delivery options. We offer competitive prices and personalized service. Get in touch today to see how we can support your business effectively and efficiently.

Comments

No comments yet

Write a comment