Pepperl+Fuchs LB4106A
HART Output Isolator

Pepperl+Fuchs LB4106A
  • 4-channel
  • Outputs Ex ia
  • Mounting in Zone 2, Class I/Div.2 or in the safe area
  • Analog output module for 0/4 mA ... 20 mA
  • HART communication via field bus or service bus
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD): one LED per channel
  • Permanently self-monitoring
  • Module can be exchanged under voltage
Item Number: LB4106A
1059.01
-
+
Total price: 1059.01
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Shock resistanceEN 60068-2-27:2009
HART secondary variableyes
Load750 andOmega; max.
Dimensions16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)
Vibration resistanceEN 60068-2-6:2008
Number of channels4
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Connectionterminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-
HART secondary variableno
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
Massapprox. 90 g
Connectionbackplane bus
Power dissipation2.15 W
Environmental testEN 60068-2-14:2009
Relative humidity95 % non-condensing
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Current0 ... 26 mA short-circuit protected
Degree of protectionIP20 when mounted on backplane
Rated voltage12 V DC , only in connection with the power supplies LB9***
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
LED indicationPower LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (1-4) red: line fault (lead breakage or short circuit)
Electromagnetic compatibilityNE 21:2007
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
HART communicationyes
ATEX approvalBVS 11 ATEX E 116X
Codingoptional mechanical coding via front socket
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Relative humidityEN 60068-2-78:2001
Interfacemanufacturer-specific bus to standard com unit
IECEx approvalBVS 11.0068X
Power consumption3.3 W
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
HART communicationyes
Occupied slots1
Connectionbackplane bus
EU-Type Examination CertificateBVS 11 ATEX E 116 X
UL approvalE106378
Degree of protectionIEC 60529:2000
Damaging gasEN 60068-2-42:2003