Pepperl+Fuchs LB5105A
Thermocouple Converter

Pepperl+Fuchs LB5105A
  • 4 channels
  • Inputs Ex ia
  • Mounting in Zone 2, Class I/Div.2 or in the safe area
  • Converter for thermocouples and mV-signals
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring
  • Module can be exchanged under voltage
Item Number: LB5105A
752.00
-
+
Total price: 752.00
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Power dissipation0.75 W
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
CertificatePF 08 CERT 1234 X
Measurement range-65 ... 75 mV with LFD , -75 ... 75 mV without LFD
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Massapprox. 150 g
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Vibration resistanceEN 60068-2-6
Connectionchannel I: 1+, 2-; channel II: 5+, 6-; channel III: 9+, 10-; channel IV: 13+, 14-
Degree of protectionIP20 when mounted on backplane
Dimensions32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
ATEX approvalPTB 03 ATEX 2042
Codingoptional mechanical coding via front socket
LED indicationPower LED (P) green: supply
Status LED (I) red: line fault (collective alarm) , red flashing: communication error
Compensation (reference junction CJC)internal cold junction compensation or external cold junction
Linearity error0.1 %
Number of channels4
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Electromagnetic compatibilityNE 21
Line fault detectioncan be switched on/off for each channel via configuration tool ,
Environmental testEN 60068-2-14
Smallest span5 mV for 0.1 % accuracy
Power consumption0.75 W
Shock resistanceEN 60068-2-27
Degree of protectionIEC 60529
Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies LB9***
IECEx approvalBVS 09.0037X
EU-Type Examination CertificatePTB 03 ATEX 2042
Relative humidity95 % non-condensing
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Interfacemanufacturer-specific bus to standard com unit
Damaging gasEN 60068-2-42
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Relative humidityEN 60068-2-56
Compensation (reference junction CJC)internal cold junction compensation or external cold junction
UL approvalE106378
Conversion timemax. 300 ms (4 channels) without LFD max. 600 ms (4-channel) with LFD
Connectionbackplane bus
Occupied slots2