Pepperl+Fuchs LB6008A
Digital Output with Shutdown Input
- 8-channel
- Galvanic group isolation
- Installation in Zone 2 or safe area
- Module can be exchanged under voltage
- Line fault detection (LFD)
- Positive or negative logic selectable
- Simulation mode for service operations (forcing)
- Permanently self-monitoring
- Output with watchdog
- Output with bus-independent safety shutdown
Item Number:
LB6008A
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
EAC approval | Russia: RU C-IT.MIII06.B.00129 |
Interface | manufacturer-specific bus to standard com unit |
Degree of protection | IEC 60529 |
Shock resistance | EN 60068-2-27 |
Degree of protection | IP20 when mounted on backplane |
Connection | channel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8-; channel V: 9+, 10-; channel VI: 11+, 12-; channel VII: 13+, 14-; channel VIII: 15+, 16- |
Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication |
Connection | backplane bus |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Connection | backplane bus |
Coding | optional mechanical coding via front socket |
Environmental test | EN 60068-2-14 |
Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance |
Mass | approx. 160 g |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Response time | 20 ms (depending on bus cycle time) |
Open loop voltage | 20 V |
ATEX approval | PF 08 CERT 1234 X |
Electromagnetic compatibility | NE 21 |
System information | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure. |
Relative humidity | 95 % non-condensing |
Vibration resistance | EN 60068-2-6 |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) , 70 В°C (non-Ex) |
Occupied slots | 2 |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) |
Number of channels | 8 |
Damaging gas | EN 60068-2-42 |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Certificate | PF 08 CERT 1234 X |
Power consumption | 2.35 W |
Safety Integrity Level (SIL) | SIL 2 |
Dimensions | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
Power dissipation | 2.35 W |
LED indication | LED green: supply LED red: line fault , red flashing: communication error |
IECEx approval | BVS 09.0037X |
Current limit | 8 mA |
Line fault detection | can be switched on/off for each channel via configuration tool |
Rated voltage | 12 V DC , only in connection with the power supplies LB9*** |
Relative humidity | EN 60068-2-56 |