Pepperl+Fuchs LB6110AR
Digital Output
- 4-channel
- Outputs Ex ia
- Installation in Zone 2 or safe area
- Line fault detection (LFD)
- Positive or negative logic selectable
- Simulation mode for service operations (forcing)
- Permanently self-monitoring
- Output with watchdog
Item Number:
LB6110AR
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Damaging gas | EN 60068-2-42 |
Vibration resistance | EN 60068-2-6 |
Reaction time | 10 s |
Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Connection | backplane bus |
Interface | manufacturer-specific bus to standard com unit |
Rated voltage | 12 V DC , only in connection with the power supplies LB9*** |
Mass | approx. 150 g |
Certificate | PF 08 CERT 1234 X |
Degree of protection | IEC 60529 |
Environmental test | EN 60068-2-14 |
LED indication | Power LED (P) green: supply Status LED (I) red: line fault , red flashing: communication error |
Response time | 10 ms (depending on bus cycle time) |
Shock resistance | EN 60068-2-27 |
Current limit | 37 mA |
Coding | optional mechanical coding via front socket |
IECEx approval | BVS 09.0037X |
Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication |
Dimensions | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
ATEX approval | PTB 03 ATEX 2042 X |
Power consumption | 0.15 W |
Input voltage range | 18.5 ... 32 V DC (SELV/PELV) booster voltage |
Electromagnetic compatibility | NE 21 |
Connection | backplane bus / booster terminals |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Relative humidity | EN 60068-2-56 |
Occupied slots | 2 |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Line fault detection | can be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms) |
Relative humidity | 95 % non-condensing |
Open loop voltage | 24.5 V |
Power dissipation | 3 W |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Number of channels | 4 |
Connection | channel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8- |
System information | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure. |
EU-type examination certificate | PTB 03 ATEX 2042 X |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Degree of protection | IP20 when mounted on backplane |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) |
Internal resistor | max. 370 Ω |