Pepperl+Fuchs LB6110ER
Digital Output with Shutdown Input

Pepperl+Fuchs LB6110ER
  • 4-channel
  • Outputs Ex ia
  • Installation in Zone 2 or safe area
  • Line fault detection (LFD)
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Permanently self-monitoring
  • Output with watchdog
  • Output with bus-independent safety shutdown
Item Number: LB6110ER
893.83
-
+
Total price: 893.83
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Reaction time10 s
Internal resistormax. 370 Ω
Electromagnetic compatibilityNE 21
Dimensions32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Response time10 ms (depending on bus cycle time)
Relative humidityEN 60068-2-56
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
Interfacemanufacturer-specific bus to standard com unit
Degree of protectionIEC 60529
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Environmental testEN 60068-2-14
Codingoptional mechanical coding via front socket
Open loop voltage24.5 V
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Input voltage range18.5 ... 32 V DC (SELV/PELV) booster voltage
Occupied slots2
Current limit37 mA
EU-type examination certificatePTB 03 ATEX 2042 X
Connectionbackplane bus
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Vibration resistanceEN 60068-2-6
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
LED indicationPower LED (P) green: supply
Status LED (I) red: line fault , red flashing: communication error
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
CertificatePF 08 CERT 1234 X
Rated voltage12 V DC , only in connection with the power supplies LB9***
Safety Integrity Level (SIL)SIL 2
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
IECEx approvalBVS 09.0037X
Shock resistanceEN 60068-2-27
Connectionbackplane bus / booster terminals
Damaging gasEN 60068-2-42
Number of channels4
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Line fault detectioncan be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms)
Relative humidity95 % non-condensing
Power dissipation3 W
ATEX approvalPTB 03 ATEX 2042 X
Degree of protectionIP20 when mounted on backplane
Connectionchannel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8-
Massapprox. 150 g
Power consumption0.15 W
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18