Pepperl+Fuchs LB6115AR
Digital Output

Pepperl+Fuchs LB6115AR
We ship to United States of America!
  • 4-channel
  • Outputs Ex ia
  • Installation in Zone 2 or safe area
  • Line fault detection (LFD)
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Permanently self-monitoring
  • Output with watchdog
Item Number: LB6115AR
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview +
  • Comments +
Open loop voltage16.6 V
Number of channels4
Storage temperature-25 ... 85 ?°C (-13 ... 185 ?°F)
Power dissipation3 W
Electromagnetic compatibilityNE 21
ATEX approvalPTB 03 ATEX 2042 X
LED indicationPower LED (P) green: supply
Status LED (I) red: line fault , red flashing: communication error
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
EU-type examination certificatePTB 03 ATEX 2042 X
Internal resistormax. 90 Ω
Line fault detectioncan be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms)
Connectionchannel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8-
Degree of protectionIP20 when mounted on backplane
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
IECEx approvalBVS 09.0037X
Ambient temperature-20 ... 60 ?°C (-4 ... 140 ?°F)
Occupied slots2
Codingoptional mechanical coding via front socket
Relative humidity95 % non-condensing
Rated voltage12 V DC , only in connection with the power supplies LB9***
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Power consumption0.15 W
Connectionbackplane bus / booster terminals
Reaction time10 s
Interfacemanufacturer-specific bus to standard com unit
Massapprox. 150 g
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Environmental testEN 60068-2-14
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Dimensions32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Relative humidityEN 60068-2-56
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Input voltage range18.5 ... 32 V DC (SELV/PELV) booster voltage
Vibration resistanceEN 60068-2-6
Shock resistanceEN 60068-2-27
Current limit70 mA
Response time10 ms (depending on bus cycle time)
Connectionbackplane bus
CertificatePF 08 CERT 1234 X
Degree of protectionIEC 60529
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ?± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ?± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasEN 60068-2-42

Buy Pepperl+Fuchs LB6115AR with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. offers premium industrial control products. Our vast inventory and express delivery options ensure you receive your order quickly. We prioritize quality and customer satisfaction. Contact us today to learn more about our offerings and how we can assist your business.

Comments

No comments yet

Write a comment