Pepperl+Fuchs LB8109*
Unicom Com Unit for PROFIBUS DP/DP-V1

Pepperl+Fuchs LB8109*
  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via PROFIBUS DP
  • Mounting in Zone 2, Class I/Div.2 or in the safe area
  • HART communication via PROFIBUS DP V1 or service bus
  • Configuration via FDT 1.2 DTM
  • Configuration in run (CiR) for any PCS
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Module can be exchanged under voltage
Item Number: LB8109*
969.00
-
+
Total price: 969.00
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Massapprox. 120 g
Addressingvia configuration software
Electromagnetic compatibilityNE 21
Connectionbackplane bus
HART communicationvia PROFIBUS or service bus
Configuration (240 bytes I/O)Standard: 80 analog, 184 digital
Universal 2I2O: 48 analog, 184 digital
Universal 4I4O: 60 analog, 120 digital
Supported I/O modulesall LB remote I/O modules
Cyclic process data240 bytes input and (simultaneously) 240 bytes output
Connectionvia backplane
GSE fileCGV61710.gsd/gse
Number of stations per bus segmentmax. 31 (RS-485 standard)
ATEX approvalPF 08 CERT 1234 X
Bus lengthmax. 1000 m (FOL, 1.5 MBaud),
max. 1000 m (copper cable, 187.5 kBd),
max. 200 m (copper cable, 1.5 MBd)
UL approvalE106378
Degree of protectionIP20 (module) , mounted on backplane
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
CertificatePF 08 CERT 1234 X
Dimensions32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Rated voltage5 V DC , only in connection with the power supplies LB9***
Fieldbus typePROFIBUS DP/DP-V1
Power consumption2 W
LED indicatorLED 1 (power supply): On = operating, fast flash = cold start, slow flash = HCIR loading active
LED 2 (collective alarm): On = internal fault, flashing = no PROFIBUS connection
LED 3 (status process bus): flashing = PROFIBUS receive channel active
LED 4 (status service bus): flashing = service bus receive channel active
LED 5 (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation
LED 6 (status process bus): flashing = PROFIBUS response channel active
LED 7 (status servicebus): flashing = service bus response channel active
EAC approvalRussia: RU C-IT.MIII06.B.00129
PROFIBUS address0 ... 126
(factory standard setting: 126)
IECEx approvalBVS 09.0037X
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Number of repeaters between Master and Slavemax. 3
Redundancyvia backplane
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Degree of protectionIEC 60529
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Connectionbackplane bus
Number of stations per bus linemax. 125 (PROFIBUS), max. 119 (service bus)
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance

Comments

No comments yet

Write a comment