Pepperl+Fuchs LB8109H0907
Unicom Com Unit for PROFIBUS DP/DP-V1

Pepperl+Fuchs LB8109H0907
  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via PROFIBUS DP
  • Mounting in Zone 2, Class I/Div.2 or in the safe area
  • HART communication via PROFIBUS DP V1 or service bus
  • Configuration via FDT 1.2 DTM
  • Configuration in run (CiR) for any PCS
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Module can be exchanged under voltage
Item Number: LB8109H0907
1110.32
-
+
Total price: 1110.32
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
EAC approvalRussia: RU C-IT.MIII06.B.00129
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
IECEx approvalBVS 09.0037X
Configuration (240 bytes I/O)Standard: 80 analog, 184 digital
Universal 2I2O: 48 analog, 184 digital
Universal 4I4O: 60 analog, 120 digital
GSE filePFV61711.gsd/gse
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Fieldbus standardIEC 61158-2
Damaging gasEN 60068-2-42
Power consumption1.8 W
Connectionbackplane bus
Degree of protectionIEC 60529
Dimensions32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Addressingvia configuration software
LED indicationLED P: (power supply): On = operating, fast flash = cold start
LED 1: (collective alarm): On = internal fault, flashing = no fieldbus connection
LED 2: (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation
LED 3: (status fieldbus): flashing = fieldbus receive channel active
LED 4: (status fieldbus): flashing = fieldbus response channel active
LED 5: (status service bus): flashing = service bus receive channel active
LED 6: (status service bus): flashing = service bus response channel active
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Electromagnetic compatibilityNE 21
Relative humidity95 % non-condensing
PROFIBUS address0 ... 126
(factory standard setting: 126)
Number of stations per bus linemax. 125 (PROFIBUS), max. 119 (service bus)
Supported I/O modulesall LB remote I/O modules
UL approvalE106378
Fieldbus typePROFIBUS DP/DP-V1
Connectionbackplane bus
Shock resistanceEN 60068-2-27
Number of repeaters between Master and Slavemax. 3
Cyclic process data240 bytes input and (simultaneously) 240 bytes output
Environmental testEN 60068-2-14
Rated voltage5 V DC , only in connection with the power supplies LB9***
Relative humidityEN 60068-2-56
Massapprox. 120 g
CertificatePF 08 CERT 1234 X
Redundancyvia backplane
Degree of protectionIP20 (module) , mounted on backplane
Power dissipation1.8 W
Vibration resistanceEN 60068-2-6
HART communicationvia PROFIBUS or service bus
ATEX approvalPF 08 CERT 1234 X
Bus lengthmax. 1000 m (FOL, 1.5 MBaud),
max. 1000 m (copper cable, 187.5 kBd),
max. 200 m (copper cable, 1.5 MBd)
Number of stations per bus segmentmax. 31 (RS-485 standard)
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Connectionvia backplane

Comments

No comments yet

Write a comment