Pepperl+Fuchs LB8111A2-0756
Com Unit for MODBUS TCP

Pepperl+Fuchs LB8111A2-0756
  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via MODBUS TCP
  • Mounting in Zone 2, Class I/Div.2 or in the safe area
  • HART communication via MODBUS TCP or service bus
  • Configuration via FDT 1.2 DTM
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Module can be exchanged under voltage
Item Number: LB8111A2-0756
1294.00
-
+
Total price: 1294.00
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Environmental testEN 60068-2-14

Power consumption2.5 W
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
IECEx approvalBVS 09.0037X
Degree of protectionIEC 60529
UL approvalE106378
Fieldbus typeMODBUS TCP
Damaging gasEN 60068-2-42
Relative humidityEN 60068-2-56
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Power dissipation2.5 W
Supported I/O modulesall LB remote I/O modules
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Massapprox. 150 g
Connectionbackplane bus
Bus lengthmax. 100 m (CAT 7 cable)
LED indicationLED P: (power supply): On = operating, fast flash = cold start
LED 1: (collective alarm): On = internal fault, flashing = no fieldbus connection
LED 2: (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation
LED 3: (status fieldbus): flashing = fieldbus receive channel active
LED 4: (status fieldbus): flashing = fieldbus response channel active
LED 5: (status service bus): flashing = service bus receive channel active
LED 6: (status service bus): flashing = service bus response channel active
Fieldbus standardIEEE 802.3
Connection typeRJ-45 , via backplane
CertificatePF 08 CERT 1234 X
Number of channels per stationmax. 80 analog, max. 184 digital
Rated voltage5 V DC , only in connection with the power supplies LB9***
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
HART communicationvia Ethernet or service bus
Connectionbackplane bus
Dimensions32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Redundancyvia backplane
Degree of protectionIP20 (module) , mounted on backplane
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Shock resistanceEN 60068-2-27
Relative humidity95 % non-condensing
Connection9-pole to RS 485 standard , Sub-D
Vibration resistanceEN 60068-2-6
Number of stations per bus line31 (RS-485 standard)
AddressingIP address assigned via Ethernet
Connectionvia backplane
Station connectiondirectly to PCS or PLC or via hubs or switches
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Ethernet addressIP V4 address (factory standard setting: 0.0.0.0, auto IP, DHCP)
ATEX approvalPF 08 CERT 1234 X
EAC approvalRussia: RU C-IT.MIII06.B.00129
Transfer rate10 MBit/s