Pepperl+Fuchs LC10-2-D 115 VAC Loop detector


Item Number: LC10-2-D 115 VAC
- Sensor system for vehicle detection
- Complete control interface for inductive loops laid beneath the surface
- Reliable detection with long service life
- Boost function for increasing sensitivity
- Test function
- Version with 2 loop channels
- Version with direction detection
- Overview
- Datasheet
- Alternative numbers
- Comments
Calibration time | 2 s |
Response time | 200 ms |
Control elements | DIP-switch |
Loop inductivity | 100 ... 1000 andmicro;H |
Degree of protection | IP30 |
Ambient temperature | -20 ... 70 В°C (-4 ... 158 В°F) |
Ripple | -15 %/+10 % |
Number of channels | 2 |
MTTFd | 306 a |
Operating voltage | 115 V AC ( galvanically isolated from loop ) |
Loop frequency | 20 ... 120 kHz |
Mission Time (TM) | 20 a |
Marking | CE |
Switching state | LED |
Power consumption | 2.2 VA |
Connection | Plug socket ; 11-pin Terminal connection 1.5 mm2 |
Pulse length | period |
Switching current | 6 A |
Switching voltage | 250 V AC |
Storage temperature | -40 ... 70 В°C (-40 ... 158 В°F) |
Operating mode | Continuous signal / Direction detection |
Signal output | 2 relay outputs |
People also buy
Comments