Pepperl+Fuchs LD28/LV28-F2/47/76a/82b/105
Thru-beam sensor

Pepperl+Fuchs LD28/LV28-F2/47/76a/82b/105
  • Ultra bright LEDs for power on, weak signal indication and switching state
  • Highly visible LED as alignment aid in receiver optics
  • Emitter deactivation
  • Various transmitter frequencies
  • Not sensitive to ambient light, even with switched energy saving lamps
  • Waterproof, degree of protection IP67
  • Protection class II
Item Number: LD28/LV28-F2/47/76a/82b/105
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Diameter of the light spotapprox. 0.6 m at 30 m
Protection classII, rated voltage 250 V AC with pollution degree 1-2 according to IEC 60664-1
Response time0.5 ms
Signal output2 PNP, complementary, short-circuit protected, reverse polarity protected , open collectors
Pre-fault indication output1 PNP transistor, short-circuit protected, protected from reverse polarity, open collector, Umax = 30 V DC, Imax = 0.2 A
The output becomes inactive if the signal level has fallen below the function reserve for approx. 10 s (yellow and red LEDs flash).
If the light beam is interrupted four times during this period, the output immediately becomes inactive.
Light sourceLED
UL approvalcULus
Angle of divergenceEmitter 1.2В°,
Receiver 5В°
Transmitter frequencyF2 = 30 kHz
Housing height88 mm
MTTFd620 a
Alignment aidLED red (in receiver lens)
illuminated constantly: beam is interrupted,
flashes: reaching switching point,
off: sufficient stability control
Ripple10 %
Mass140 g (emitter and receiver)
Product standardEN 60947-5-2
CCC approvalCCC approval / marking not required for products rated 36 V
Switching voltagemax. 30 V DC
Ambient temperature-40 ... 60 В°C (-40 ... 140 В°F)
Storage temperature-40 ... 75 В°C (-40 ... 167 В°F)
ReceiverLV28-F2/47/82b/105
Operating voltage10 ... 30 V DC
Threshold detection range40 m
Function indicatorLED yellow:
1. LED lit constantly: signal > 2 x switching point (function reserve)
2. LED flashes: signal between 1 x switching point and 2 x switching point
3. LED off: signal < switching point
Switching frequency1000 Hz
Mission Time (TM)20 a
Housing width25.8 mm
Degree of protectionIP67
Test inputemitter deactivation at +UB (Imax. < 3 mA at 30 V DC)
No-load supply currentEmitter: 50 mA
Receiver: 35 mA
Operation indicatorLED green
Housing depth54.3 mm
Connection5-pin, M12 x 1 plastic connector
Diagnostic Coverage (DC)90 %
Ambient light limit50000 Lux
Switching currentmax. 200 mA
Effective detection range0 ... 30 m
Switching typelight/dark on, switchable
Control elementssensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-on/dark-on changeover switch
Light typemodulated visible red light , 660 nm
EmitterLD28-F2/76a/105

Comments

No comments yet

Write a comment