Pepperl+Fuchs LHC-M51
Pressure Transmitter

Pepperl+Fuchs LHC-M51
  • Device for absolute pressure and gauge pressure measurement in gases, steams or liquids
  • Large selection of process connections: universal use
  • Temperature range up to 130 В°C (266 В°F)
  • Pressure range up to 400 bar (6000 psi)
  • Easy commissioning without the need for an operating tool
  • Configurable by PACTware
  • Up to SIL 2 acc. to IEC 61508
Item Number: LHC-M51
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Accuracyreference accuracy: В±0.15 % (standard), В±0.075 % (platinum)
The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and non-reproducibility acc. to IEC 60770. The data refer to the calibrated span.
Overspill protectionsee approval (ZE)
Communication4 ... 20 mA HART (standard)
PROFIBUS PA (option)
Rated voltageversions for safe area:
11.5 ... 45 V DC, 2-wire
11.5 ... 35 V DC, HART, 2-wire
9 ... 32 V DC, PROFIBUS PA
version for hazardous area see safety information (SI)
Long-term driftup to В±0.1 % of upper range limit (URL)/year
Degree of protectionIP66, NEMA 4X
IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep)
IP69K (with separate housing and FEP cable)
Process connectionthreads ISO 228: G1/2, G1, G1-1/2, G2
threads ANSI: NPT1/2, NPT1, NPT1-1/2, NPT2
hygienic process connections: Clamp, Varivent, DRD, DIN 11851, DIN 11864, NEUMO, APV, uni adapter
flanges: EN 1092-1: DN 25 ... DN 80, ANSI 16.5: 1 ... 4 inch, JIS B2220
Measured variableabsolute or relative pressure
Measurement range0.4 ... 400 bar
max. turn down: 100:1
Drinking water approvalNSF61 approval
Degree of protectionIEC 60529:2001
Marine approvalGerman Lloyd (GL)
FM approvalsee instruction manuals (SI)
Construction typesensor: silicium sensor
metall diaphragm
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
IECEx approvalsee instruction manuals (SI)
Supplementary documentationtechnical information (TI)
manuals, brief instructions (BA, KA)
instruction manuals (SI)
control drawings (ZD)
approval (ZE)
Materialmaterials in contact with process : 316L, Alloy C, rhodium>gold
housing:
- die-cast aluminum with protective powder-coating on polyester base, housing F31
- stainless steel AISI 316L (1.4404), housing F15
measuring cell seal: no, welded measuring cell
EU-Type Examination Certificatesee instruction manuals (SI)
Designationsee technical information (TI)
CSA approvalsee instruction manuals (SI)
Connectiongland M20
thread M20, G1/2, NPT1/2
device plug M12
HAN7D Harting connector, angled
valve connector acc. ISO 4400, cable 5 m
Output signal4 ... 20 mA , analog , 2-wire
4 ... 20 mA with superimposed digital communication protocol HART 6.0, 2-wire
digital communication signal PROFIBUS PA (Profile 3.02)
Ambient temperature-40 ... 85 В°C (-40 ... 185 В°F)
with display : -20 ... 70 В°C (-4 ... 158 В°F)