Pepperl+Fuchs LTC50
Guided Level Radar

Pepperl+Fuchs LTC50
  • Basic device for level measurement in liquids
  • Measuring range up to 12 m (39 ft)
  • Process connection 3/4 in thread or with adapter flange
  • Temperature range up to 80 В°C (176 В°F)
  • Pressure range up to 6 bar (87 psi)
  • Up to SIL3 acc. to IEC 61508
Item Number: LTC50
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Degree of protectionIP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep)
IP66, NEMA 4X
IECEx approvalsee instruction manuals (SI)
Process connectionthreads: G3/4, MNPT3/4
flanges: universal flange
Degree of protectionIEC 60529:2001
Measured variabledistance between reference point and product surface
Designationsee technical information (TI)
Ambient temperature-40 ... 80 В°C (-40 ... 176 В°F)
Overspill protectionsee approval (ZE)
Output signal4 ... 20 mA
2 x 4 ... 20 mA
Measuring methodThe device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured.
EC-Type Examination Certificatesee instruction manuals (SI)
Measurement rangerod probe: 4 m (13 ft)
rope probe: 12 m (39 ft)
Accuracydigital: В±2 mm (0.08 inch)
analog: 0.02 %
sum of non-linearity, non-repeatability and hysteresis included in the maximum measured error
Connectiongland M20
thread M20, G1/2, NPT1/2
device plug M12, 7/8 in
Materialmaterials in contact with process :
rod probe: 1.4404/316L
rope probe: 1.4401/316
process connections: 1.4404/316L, PPS-GF40
process membran, seal: Viton
Telecommunicationsradio license FCC
Rated voltage11.5 ... 35 V DC, 2-wire
10.4 ... 48 V DC, 4-wire
90 ... 253 V AC, 50/60 Hz
Construction typedevice with rod probe
device with rope probe
Communication4 ... 20 mA HART (standard)
PROFIBUS PA (option)

Comments

No comments yet

Write a comment