Pepperl+Fuchs MLV41-8-H-350-RT/59/115/136 Background suppression sensor


Item Number: MLV41-8-H-350-RT/59/115/136
- Rugged series in corrosion-resistant metal housing
- Reliable detection of all surfaces, independent of color and structure
- Minimal black-white difference
- Precision background suppression, adjustable
- Extremely high switching frequency
- Clear and functional display concept for the operating modes
- Overview
- Datasheet
- Alternative numbers
- Comments
Background suppression | + 10 % of the upper limit of the detection range |
Light source | LED |
Function indicator | 2 LEDs yellow ON: object inside the scanning range OFF: object outside the scanning range |
Ambient light limit | 40000 Lux |
Control elements | Sensing range adjuster |
Light type | modulated visible red light , 660 nm |
MTTFd | 1260 a |
Degree of protection | IP67 |
Mission Time (TM) | 20 a |
Switching voltage | max. 30 V DC |
No-load supply current | max. 25 mA |
Switching current | max. 100 mA |
Ripple | max. 10 % |
Angle of divergence | 1.5 В° |
Connection | 2 m fixed cable |
Switching frequency | 1000 Hz |
Detection range | 50 ... 350 mm , adjustable |
Adjustment range | 50 ... 350 mm |
Black/White difference (6 %/90 %) | < 15 % at 350 mm |
Housing width | 31 mm |
Housing height | 56.5 mm |
Diagnostic Coverage (DC) | 0 % |
CCC approval | CCC approval / marking not required for products rated 36 V |
Diameter of the light spot | approx. 8 mm at 350 mm sensor range |
Detection range max. | 30 ... 350 mm |
Housing depth | 13.6 mm |
Storage temperature | -40 ... 75 В°C (-40 ... 167 В°F) |
UL approval | cULus Listed 57M3 (Only in association with UL Class 2 power supply; Type 1 enclosure) |
Operating voltage | 10 ... 30 V DC |
Response time | 0.5 ms |
Mass | 100 g |
Voltage drop | 2.5 V DC |
Detection range min. | 10 ... 50 mm |
Operation indicator | LED green, statically lit Power on , Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) , short-circuit : LED green flashing (approx. 4 Hz) |
Ambient temperature | -40 ... 60 В°C (-40 ... 140 В°F) |
Signal output | 2 push-pull (4 in 1) outputs, complementary, short-circuit proof, reverse polarity protected |
Protection class | II, rated voltage 50 V AC with pollution degree 1-2 according to IEC 60664-1 , functional insulation acc. to DIN EN 50178 |
People also buy
Comments
No comments yet