Pepperl+Fuchs NBB2-8GM40-E2-0,3M-V3
Inductive sensor
- Overview
- Comments
Output typePNP
2 mm flush
Increased operating distance
Extended temperature range
-40 ... +85 В°C
Degree of protection | IP67 |
Reduction factor rAl | 0.4 |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Installation | flush |
Housing material | brass, nickel-plated |
Diagnostic Coverage (DC) | 0 % |
Reduction factor r304 | 0.75 |
Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm |
Scope of delivery | 2 hex nuts included |
Connection type | Cable connector M8 x 1 , 3-pin with PVC cable 300 mm |
Sensing face | LCP |
No-load supply current | 10 mA |
Reduction factor rCu | 0.3 |
Voltage drop | 1.5 V |
Reverse polarity protection | reverse polarity protected |
CCC approval | CCC approval / marking not required for products rated 36 V |
MTTFd | 960 a |
Output type | 3-wire |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Output polarity | DC |
Hysteresis | typ. 5% |
Reduction factor rBrass | 0.45 |
Assured operating distance | 0 ... 1.62 mm |
Operating voltage | 5 ... 30 V |
Operating current | 0 ... 100 mA |
Rated operating distance | 2 mm |
Time delay before availability | 100 ms |
Ambient temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Core cross-section | 0.14 mm2 |
Mission Time (TM) | 20 a |
Short-circuit protection | pulsing |
Switching state indicator | LED, yellow |
Switching function | Normally open (NO) |
Off-state current | 0 ... 0.2 mA |
Switching frequency | 0 ... 6000 Hz |
Comments