Pepperl+Fuchs NBB5-18GM60-WO-V12
Inductive sensor

- 5 mm flush
- 2-wire AC

Item Number:
NBB5-18GM60-WO-V12
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Datasheet
- Alternative numbers
- Comments
Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA |
Installation | flush |
Reverse polarity protection | reverse polarity tolerant |
Mission Time (TM) | 20 a |
Operating current | 5 ... 200 mA |
Switching function | Normally closed (NC) |
Output type | Two-wire |
Voltage drop | < 5 V (IL > 50 mA); < 8 V (IL < 50 mA) |
Switching frequency | 0 ... 20 Hz |
Off-state current | 0 ... 1.7 mA typ. |
Degree of protection | IP67 |
Output polarity | AC |
Reduction factor r304 | 0.6 |
Operating voltage indicator | LED, green |
Sensing face | PBT |
MTTFd | 1135 a |
Diagnostic Coverage (DC) | 0 % |
UL approval | cULus Listed, General Purpose |
Assured operating distance | 0 ... 4.05 mm |
Output type | 2-wire |
Operating voltage | 20 ... 253 V |
Rated operating distance | 5 mm |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Connection type | Connector plug 1/2""-20 UN , 3-pin |
Hysteresis | typ. 6 % |
CSA approval | cCSAus Listed, General Purpose |
Housing material | brass, nickel-plated |
Reduction factor rCu | 0.2 |
CCC approval | Certified by China Compulsory Certification (CCC) |
Switching state indicator | LED, yellow |
Reduction factor rAl | 0.2 |
Note | 1) In the temperature range below 0 В°C, permissible operating voltage Ub 80...253 V Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
Actual operating distance | 4.5 ... 5.5 mm typ. 5 mm |
People also buy
Comments