Pepperl+Fuchs NCB1,5-12M35-N0-V1-Y125502
Inductive sensor

Pepperl+Fuchs NCB1,5-12M35-N0-V1-Y125502
  • 1.5 mm flush
  • 0...1.21mm
  • 2 sons
Item Number: NCB1,5-12M35-N0-V1-Y125502
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Appropriate typeNCB1,5...M...N0...NAMUR sensors must be operated with approved switch amplifiers.

CE marking[*PD-Z02585A*]
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
Appropriate typeNCB1,5...M...N0...
CSA approvalcCSAus Listed, General Purpose
Effective internal inductancemax. 100 µH ; a cable length of 10 m is considered.
Reduction factor rCu0.3
Output type2-wire
Effective internal capacitancemax. 90 µF
A cable length of 10 m is considered.
Switching functionNormally closed (NC)
Effective internal inductancemax. 100 µH
A cable length of 10 m is considered.
ATEX marking II 1D Ex ia IIIC T135В°C Da
The Ex-related marking can also be printed on the enclosed label.
Switching frequency0 ... 2000 Hz
Installationflush
Use in the hazardous areasee instruction manuals
Nominal voltage8 V
Reduction factor rAl0.4
ATEX marking II 2G Ex ia IIC T6…T1 Gb
The Ex-related marking can also be printed on the enclosed label.
Sensing facePBT
Housing materialStainless steel 1.4305 / AISI 303
Effective internal capacitancemax. 90 nF ; a cable length of 10 m is considered.
Rated operating distance1.5 mm
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
Output typeNAMUR
Degree of protectionIP67
UL approvalcULus Listed, General Purpose
Connection typeConnector plug M12 x 1 , 4-pin
Reduction factor r3040.85
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
CE marking[*PD-Z02585A*]
Assured operating distance0 ... 1.21 mm

Comments

No comments yet

Write a comment