Pepperl+Fuchs NCB1,5-8GM40-N0-V1-Y97264
Inductive sensor
- Comfort series
- 1.5 mm flush
- Overview
- Comments
Appropriate type | NCB1,5...M...N0... |
Effective internal inductance | max. 100 andmicro;H ; a cable length of 10 m is considered. |
Connection type | Connector plug M12 x 1 , 4-pin |
Housing material | brass, nickel-plated |
Effective internal inductance | max. 100 andmicro;H ; a cable length of 10 m is considered. |
ATEX marking | II 1D Ex ia IIIC T135В°C Da The Ex-related marking can also be printed on the enclosed label. |
Effective internal capacitance | max. 90 nF ; a cable length of 10 m is considered. |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. |
Reduction factor rAl | 0.22 |
Degree of protection | IP67 |
Rated operating distance | 1.5 mm |
Nominal voltage | 8 V |
Switching function | Normally closed (NC) |
Installation | flush |
Output type | NAMUR |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. |
CE marking | [*PD-Z02585A*] |
Effective internal capacitance | max. 90 nF ; a cable length of 10 m is considered. |
Reduction factor rCu | 0.19 |
Sensing face | PBT |
Storage temperature | -40 ... 100 В°C (-40 ... 212 В°F) |
ATEX marking | II 1G Ex ia IIC T6andhellip;T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Effective internal capacitance | max. 90 nF ; a cable length of 10 m is considered. |
Effective internal inductance | max. 100 andmicro;H ; a cable length of 10 m is considered. |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. |
CE marking | [*PD-Z02585A*] |
UL approval | cULus Listed, General Purpose |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Appropriate type | NCB1,5...M...N0... |
Short-circuit protection | yes |
Switching state indicator | Multihole-LED, yellow |
Reverse polarity protection | reverse polarity protected |
ATEX marking | II 1G Ex ia IIC T6andhellip;T1 Ga The Ex-significant identification is on the enclosed adhesive label |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Use in the hazardous area | see instruction manuals |
Assured operating distance | 0 ... 1.215 mm |
Actual operating distance | 1.35 ... 1.65 mm typ. |
Switching frequency | 0 ... 5000 Hz |
Appropriate type | NCB1,5...M...N0... |
CE marking | [*PD-Z02585A*] |
Output type | 2-wire |
Hysteresis | 1 ... 10 typ. 3 % |
Reduction factor r304 | 0.65 |
CSA approval | cCSAus Listed, General Purpose |
People also buy